Adapter

Rating Output 12VDC/0.5A

):

Cable Color

Power Output Polarity

Black &White Alternate

Anode

Black

Cathode

RS232 Cable

Cable Color

Corresponding DB9-M Pin Number

Brown

Pin 2

Blue

Pin 3

Black

Pin 5

RS485 Cable

Cable Color

Signal definition

Red

RS485(A)

Black

RS485(B)

Power adapter and communication cable connection chart as following,

Summary of Contents for F2116

Page 1: ...del Model Product Type F2116 GPRS IP MODEM F2216 CDMA IP MODEM F2416 WCDMA IP MODEM F2616 EVDO IP MODEM F2716 TDD LTE IP MODEM F2816 FDD LTE IP MODEM F2A16 LTE IP MODEM Xiamen Four Faith Communication Technology Co Ltd Add J1 J3 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China Zip Code 361008 Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 http en fourfaith com ...

Page 2: ...files are protected by copyright law and all copyrights are reserved by Xiamen Four Faith Communication Technology Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship noti...

Page 3: ...hnology Co Ltd Page 3 of 34 Add J1 J3 3rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http en fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Note There may be different components and interfaces in different model please in kind prevail ...

Page 4: ...le 6 1 4 Specifications 7 Chapter 2 Installation Introduction 11 2 1 General 11 2 2 Encasement List 11 2 3 Installation and Cable Connection 11 2 4 Power 14 2 5 Indicator Lights Introduction 14 Chapter 3 Configuration 15 3 1 Configuration Connection 15 3 2 Configuration Introduction 15 3 3 IP Modem s Parameters Configuration 16 3 3 1 Run the Configure Tools 16 3 3 2 Re Power IP Modem 17 3 3 3 Work...

Page 5: ...lular network allowing you to connect to your existing serial devices with only basic configuration It has low power consumption states in which the power consumption could be 1ower than 5mA 12VDC It has compatible digital I O channel ADC input pulse counter and pulse wave output function It has been widely used on M2M fields such as intelligent transportation smart grid industrial automation tele...

Page 6: ...422 port that can connect to serial devices directly TTL logic level RS232 interface can be customized Support intellectual mode enter into communication state automatically when powered Provide management software for remote management Support several work modes Convenient configuration and maintenance interface High performance Support TCP server and support multi TCP client connection optional ...

Page 7: ...P MODEM Standard and Band EGSM 900 GSM 1800MHz GSM 850 900 1800 1900MHz optional Compliant to GSM phase 2 2 GPRS class 10 class 12 optional Bandwidth 85 6Kbps TX power GSM850 900 33dBm GSM1800 1900 30dBm RX sensitivity 107dBm F2216 CDMA IP MODEM Standard and Band CDMA2000 1xRTT 800MHz 450MHz optional Bandwidth 153 6Kbps TX power 30dBm RX sensitivity 104dBm F2416 WCDMA IP MODEM Standard and Band UM...

Page 8: ...9 GSM GPRS EDGE 900 1800 1900MHz Bandwidth LTE TDD Download speed 61Mbps Upload speed 18Mbps TD HSPA Download speed 4 2Mbps Upload speed 2 2Mbps TD HSPA Download speed 2 2Mbps Upload speed 2 2Mbps TX power 23dBm RX sensitivity 97dBm F2816 FDD LTE IP MODEM Standard and Band LTE FDD 2600 2100 1800 900 800MHz 700 1700 2100MHz optional DC HSPA HSPA HSDPA HSUPA UMTS 850 900 2100MHz 800 850 1900 2100MHz...

Page 9: ...S485 orRS422 port 15KV ESD protection Data bits 5 6 7 8 Stop bits 1 1 5 2 Parity none even odd space mark Baud rate 1200 230400 bps 110 600bps optional Indicator Power ACT Online Antenna Cellular Standard SMA female interface 50 ohm GPS Standard SMA female interface 50 ohm lighting protection optional SIM UIM Standard 3V 1 8V user card interface 15KV ESD protection Power Terminal block interface r...

Page 10: ...ax 86 592 5912735 2G 45 55 mA3G 80 165 mA 4G 75 95mA 105 365mA 5VDC 2G 105 115 mA 3G 165 365 mA 4G 150 200mA Standby 35 50 mA 12VDC 55 105 mA 5VDC Sleep 3mA 12VDC 6mA 5VDC Physical Characteristics Item Content Housing Iron providing IP30 protection Dimensions 91x58 5x22 mm Weight 205g Environmental Limits Item Content Operating Temperature 35 75ºC 22 167 Storage Temperature 40 85ºC 40 185 Operatin...

Page 11: ...Chapter 2 Installation Introduction 2 1 General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 Cellular Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 Table 2 1 Encasement List 2 3 Inst...

Page 12: ...e female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced User Interface Signal Definition Pin Number Signal Name Default Function Extensible Function 1 PWR Power input anode N A 2 GND Power Ground N A 3 RX1 RS232 RX N A 4 TX1 RS232 TX N A 5 GND System Ground N A 6 RX2 RS232 RX Reserved compatible ADC and RS232 RX TT...

Page 13: ...m Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarity Black White Alternate Anode Black Cathode RS232 Cable Cable Color Corresponding DB9 M Pin Number Brown Pin 2 Blue Pin 3 Black Pin 5 RS485 Cable Cable Color Signal definition Red RS485 A Black RS485 B Power adapter and communication cable connection chart as following ...

Page 14: ...EM is DC 5 36V Warning When we use other power we should make sure that the power can supply power above 4W We recommend user to use the standard DC 12V 0 5A power adaptor 2 5 Indicator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator Light State Introduction Power ON IP MODEM is powered on OFF IP MODEM is powered off ACT BLINK Data is communicating OFF N...

Page 15: ...on Introduction There are two ways to configure the IP MODEM Configuration software tool All the settings are configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter co...

Page 16: ...e Configure Tools The Serial area shows the current serial port settings To configure IP MODEM please choose the correct serial port which connects to IP MODEM and the baud rate is 115200 with no parity then open the serial port If the button text is Close it shows the serial port now has been opened If the text is Open you should open the port first When the port opened the Output Info column wil...

Page 17: ...are will load current settings from IP MODEM and displays on the right configure columns It s now ready to configure Note To enter configure state for 4G device may need more time It is about 40 seconds 3 3 3 Work Mode 3 3 3 1 App protocol The IP Modem can be configured many communication protocols to adapt for different applications Note The tool will show the reference parameters according to th...

Page 18: ...xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the PROT work mode If this item is set to Yes all the transmission is transparent DCTCP This protocol is used in electric power field with TCP protocol PhoneNo Phone number DCUDP This protocol is used in electric power field with UDP protocol PhoneNo Phone number TRNS The device work as MODEM ...

Page 19: ...d phone number Max phone number is 5 for one group Show Phone Number If send phone number to serial port or not Hex To Text If convert HEX data to ASCII data or not SMSSER IP MODEM work as a SMS DTU All the data paced with special format send to any phone number he SMS from phone number will send to serial port Show Phone Number If send phone number to serial port or not Hex To Text If convert HEX...

Page 20: ... Text format Hex the flowing items are Hex format Login Packet Login packet Login Reply Login packet respond Heartbeat Packet Heart packet Heartbeat Reply Heartbeat packet respond Custom protocol Server mode It supports TCP and udp server Base Protocol TCP or UDP Listen Port Listen port for service 3 3 3 2 Trigger mode Normally IP MODEM always keeps online and always be ready for data transmission...

Page 21: ...e only the trigger phone number s SMS can trigger the IP Modem SMS Phone No Trigger phone number If it is empty sms received from any phone no can trigger the device SMS Password The content of SMS to trigger If it is empty any content of sms can trigger the device CTRL Make IP MODEM online through a phone call to IP MODEM Any phone number call can wake up IP Modem if the trigger number is empty O...

Page 22: ...dem Data Trigger Off If it was empty the IP Modem kept online If it is not empty only the data matching to the offline data can made the IP Modem offline Trigger Port Set the trigger data source from PORT1 or PORT2 Data Format Format of the trigger data Text or HEX I O Sleep and Wake up Made the IP Modem sleep or wake up via I O level If the I O was in high level or suspend the IP Modem was sleep ...

Page 23: ...ber s SMS can wake up IP Modem if the trigger number is empty Otherwise only the trigger phone number s SMS can trigger the IP Modem Data Trigger On Online data Data Trigger Off Offline data Trigger Port Set the trigger data source from PORT1 or PORT2 Data Format Format of the trigger data Text or HEX 3 3 3 3 Debug Level Debug information is used to debug software when there is software problem De...

Page 24: ...se configure the Backup DSC same as Main DSC Multi Data Service Center IP MODEM can connect with at most five DSC at the same time All the multi DSC can receive the same application data Reconnect Int s reconnect time interval in second Connect Retry Times reconnect times Back To Main Server This item is only valid when you set Data Center Number as 1 In this mode IP MODEM will switch to backup ce...

Page 25: ...enter Connection Check This item is valid only when the Data Center Number is greater than 1 When one of the configured data center lost connection IP MODEM will try to reconnect after the configured reconnect interval Reconnect Int s reconnect time interval in second Connect Retry Times reconnect times 3 3 4 3 ICMP Link Check ICMP link check send to server a icmp packet and wait reply to check th...

Page 26: ...60 is recommended in second Check Times 3 times 3 3 5 Serial port IP MODEM support three individual serial ports Port1 Port2 and RS485 All the three ports can enter configuration state The default parameters of the port with baudrate 115200 data property 8N1 The data from the three port can bind to Data center COM1 baud the baud rate of the PORT 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 ...

Page 27: ...8O1 8 Databit Odd parity 1 Stopbit Bind Center1 the data from the port send to center 1 Center2 the data from the port send to center 3 Center3 the data from the port send to center 3 Center4 the data from the port send to center 4 Center5 the data from the port send to center 5 ALL the data from the port send to all centers Close send to none COM2 The same as above RS485 The same as above 3 3 6 D...

Page 28: ...AP QueryNetMode Search the network mode for the 4G network Net Mode Net Mode AUTO EVDO WCDMA TD SCDMA CDMA GSM 3 3 6 2 PPP Redial Re dial Interval s The interval between ppp dial in second Dial Retry Times max times of ppp dial failure 3 3 6 3 DNS Parameters When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When the Data Center Number is 1...

Page 29: ...meet the max times The IP Modem will re dial Lcp Echo Enable or Disable Echo Interval s The interval should not be too small 60 is recommended in second Echo Times 3 times 3 3 7 2 Other Parameters SMS Center The local SMS center number It should set according to the local operation Heartbeat Int s Time interval sent heartbeat packet in second 3 3 7 3 Data Frame Parameters Bytes Interval MS The tim...

Page 30: ...network signal network status traffic flow and so on The Device Manage Center also query and configure the device parameters Device Manage Enable or Disable Dev ID For Manage Device ID for manage center 8 character Protocol TCP or UDP Service Address manage center server address Port manage center server port 3 3 8 2 Manage by SMS Configure the IP Modem by SMS SMS Configure Enable or Disable Confi...

Page 31: ...r configuration state while IP Modem normal work WriteParam Send parameters to IP Modem ReadParam Read All parameters of IP Modem ReadLog Read log information of IP Modem Factory Factory the IP Modem s parameters QueryVer Query the version of IP Modem Quit Quit configuration state Import Import parameters from file to IP Modem Export Export parameters from IP Modem to file CheckCard Check SIM card...

Page 32: ...l 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Appendix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK ...

Page 33: ...61008 China http en fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key continuously until IP MODEM enter configure state as following ...

Page 34: ...echnology Co Ltd Page 34 of 34 Add J1 J3 3rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http en fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 7 IP MODEM has entered configure state you can configure the parameters through AT command ...

Reviews: