Page 10
TROUBLESHOOTING
TROUBLE
LOOK FOR
REMEDY
Poor Spray Pattern
1. Tank is not pressurized.
2. Nozzle partially clogged.
3. Nozzle damaged.
4. Shut-off clogged.
1. Turn on Pump.
2. Clean Nozzle. See
Nozzle
Maintenance.
3. Replace Nozzle.
4. Clean Shut-off. See
Shut-off
Maintenance.
Battery will not Charge.
1. Charger not plugged into
outlet.
2. No lights illuminated on Pump.
Charger plugged into outlet.
3. No lights illuminated on Pump.
Charger plugged into outlet,
outlet functioning.
4. Red light continues flashing on
Pump (Battery temperature too
high for safe charging).
5. Red and Green lights flash
alternately on Pump (Battery can-
not be charged).
1. Plug Charger into outlet.
2. Check that outlet is function-
ing.
3. Replace Charger.
4. Allow Pump to cool.
5. Replace Pump.