Installing a NetIron MLX Series Router
December 2008
© 2008 Foundry Networks, Inc.
3-29
Installing a NetIron MLX-32 Router
This section describes the following tasks:
•
“Preparing the Installation Site”
•
“Unpacking a NetIron MLX-32 Router”
•
“Installing a NetIron MLX-32 Chassis in a Rack”
•
“Installing NetIron MLX-32 Modules”
•
“NetIron MLX-32 Cable Management”
•
“Installing Power Supplies in a NetIron MLX-32 Chassis”
•
“Connecting AC Power to a NetIron MLX-32 Chassis”
•
“Connecting DC Power to a NetIron MLX-32 Chassis”
•
Preparing the Installation Site
Cabling Infrastructure
Ensure that the proper cabling is installed in the site.
For information on cabling, see “NetIron MLX-32 Cable Management” on page 3-36, “Installing Power Supplies in
a NetIron MLX-32 Chassis” on page 3-45, “Attaching a Management Station” on page 3-49, and “Connecting a
NetIron MLX Series Router” on page 4-5.
Installation Location
Before installing the chassis, plan its location and orientation relative to other devices and equipment. For cooling
purposes, allow a minimum of six inches of space between the sides, front, and the back of the chassis and walls
or other obstructions. If a chassis is installed within a perforated enclosure, the perforations must have openings of
at least 60 percent of the surface.
Since you will be using a mechanical lift to move and install the chassis, make sure you allow enough working
room.
NOTE:
Make sure your site provides 200-240 AC power.
Unpacking a NetIron MLX-32 Router
The NetIron MLX-32 router ships with several items. Review the list below, and verify the contents. If any items are
missing, contact the place of purchase.
•
NetIron MLX-32 chassis with the card slots empty, and covered with upper and lower shipping panels (see
uncrating instructions next)
•
The appropriate number of interface modules, switch fabric modules, management modules, and power
supplies shipped separately
•
A total of 32 slot blanks shipped separately
•
Rack mount kit, including two L-shaped brackets and mounting screws
NOTE:
You must provide standard #12-24 pan-head screws for mounting the NetIron MLX Series chassis into a
rack.
•
Insertion/extraction tool for use with RJ-45 and fiber-optic connectors
•
CD-ROM containing software images and the user documentation (including this guide)
•
Warranty card