Maintaining the FastIron LS Hardware
September 2007
© 2007 Foundry Networks, Inc.
5 - 9
•
100FX-LR
CLI Commands
The
show media
command displays module information including link length, vendor name, vendor part number,
vendor revision, and laser wavelength.
[no] optical-monitor <alarm interval>
Use this command to configure monitoring for all ports (system-wide), a range or ports, or a single port. The
<alarm-interval> variable sets the interval in minutes between the sending of alarms and messages. The default
interval is three minutes. When monitoring is enabled, console messages, syslog messages, and SNMP traps are
sent when warranted by optical operating conditions, and a port is enabled.
show optic port/slot_number
This command displays optical monitoring information as a result of the
optical-monitor
configuration command.
Information includes:
•
temperature
•
TX power
•
RX power
•
TX bias current
Status values are:
•
low-alarm
•
low-warn
•
normal
•
high-warn