background image

2

NOTE:

If using a backer plate, go to “Using Backer Plate Mounting System” section.

1. Locate wood stud where left side of changing station will be mounted to the wall.
2. Measure up 46” (117 cm) from the floor and mark the wall. This locates the position

for the top left attachment hole.

NOTE:

Mark on wall MUST be in center of wood stud.

3. Align hole in top left corner of changing station with mark on wall and hold in place.
4. Using a level and measuring tape, mark the remaining three (3) holes. After marking holes,

set changing station down on ground.

5. Use a power drill and appropriate bit to drill four (4) holes in the wall. This may require

2 people.

NOTE 1: For wood studs:

- If finished wall surface is tile or masonry over wood studs, use

a 7/32” masonry bit for the pilot hole until you hit the wood

stud, then change to 1/8” bit.

- Use wood screws, finishing washers and flat washers

(Fig. a)

.

NOTE 2: For use with toggle anchors:

- If finished wall surface has wood studs that are not 16” on center,

has metal studs, or has an underlying surface of concrete block,

use 1/2” bit.

- Use machine screws and flat washers

(Fig. b)

.

- For holes NOT located in a wood stud, toggle anchors MUST be

used

(Fig. c)

. See “Using Toggle Anchors” section.

6. Align holes in changing station with drilled holes and secure top left corner of changing

station to wall stud using the appropriate screw and washer. Continue to secure the

three (3) remaining corners using the appropriate screws and washers as described

in

Note 1

or

Note 2

.

7. Ensure all four (4) screws are tight and snap caps over screw heads.

Using Toggle Anchors:

1. Insert metal end of toggle anchor into 1/2” hole.
2. Slide zip strip down snugly against wall.
3. Snap off break-away pieces of toggle anchor

(Fig. d)

.

4. Align holes in changing station with toggle anchors and secure top left corner of changing station to

wall using machine screws and flat washers. Continue to secure the three (3) remaining corners

using machine screws and flat washers.

5. Ensure all four (4) screws are tight and snap caps over screw heads.

INSTALLATION

A stud MUST be located and used for at least one side of the diaper changing station.

The diaper changing station is no stronger than the anchors or walls to which they are attached and, therefore, MUST be

firmly secured in order to support the weight they are intended to support. Contact an architect or building contractor

if any questions.

WARNING

Fig. a

Fig. b

Fig. c

Toggle

Anchor

Flat

Washer

Machine

Screw

Changing

Station

Changing

Station

Finishing

Washer

Wood

Screw

Wood Stud

Wood Stud

Fig. d

Wood Stud

Toggle

Anchor

Break-Away

Flat

Washer

All 4 of these locations MUST be used for safe installation. The lower holes ensure

installation through the metal brackets.

WARNING

Summary of Contents for 100-EHBP

Page 1: ...re installing diaper changing station Keep these instructions DO NOT discard WARNING SI253D Thank you for purchasing a quality Foundations product Our goal is 100 consumer satisfaction If for any reason you are not satisfied or if you have questions regarding your product or installation please contact our customer service team at 1 877 716 2757 Please DO NOT contact your distributor or reseller a...

Page 2: ...l Plate 1 3 Wood Screws PARTS LIST 3 4 Finishing Washers 3 Machine Screws 3 4 Flat Washers Toggle Anchors 1 1 4 Caps 15 3 8 390 mm 17 1 2 445 mm 34 1 4 870 mm For Wood Studs 3 4 Flat Washers For Use With Toggle Anchors Door wall plate to be mounted on outside of restroom door IMPORTANT NOTE The EZ Mount Backer Plate may or may not be included with the model you purchased The backer plate is intend...

Page 3: ...es and secure top left corner of changing station to wall stud using the appropriate screw and washer Continue to secure the three 3 remaining corners using the appropriate screws and washers as described in Note 1 or Note 2 7 Ensure all four 4 screws are tight and snap caps over screw heads Using Toggle Anchors 1 Insert metal end of toggle anchor into 1 2 hole 2 Slide zip strip down snugly agains...

Page 4: ...at exceed the total weight limit of 50 pounds 22 7 kg may cause the unit to be unstable or may cause a hazardous unstable condition to exist WARNING 8 1 4 210 mm 32 813 mm on center Top For A D A Compliance 46 117 cm A F F Fig e Fig f Locking Tab Top Of Buckle Using Backer Plate Mounting System If your changing station was supplied with a backer plate please follow these instructions If a backer p...

Reviews: