Fotoquantum FQS-180 Instruction Manual Download Page 4

Slave Trigger Model

This model offers three choices which can be set by the optical control and anti-preflash 
switch (5).
1. No optical control: the slave trigger indicator (10) is off, meaning that the slavetrigger 
model is shut down. 
2. One fire model: the slave trigger indicator (10) glows blue, meaning the flash will fire 
synchronously on one external flash. This model can act as an auxiliary lamp, varying 
the light effects.
3. Anti-preflash model: the slave trigger indicator (10) glows red, meaning the flash will 
fire synchronously on the second flash. This model can act as an auxiliary lamp, 
applicable to TTL system. And with anti-preflash function, it can work for the cameras 
equipped with one fire anti-preflash system. 

Modeling Lamp

Modeling lamp switch (6) decides whether the modeling lamp is on or off: modeling lamp 
indicator (11) on, modeling lamp is turned on; 
the indicator (11) off, modeling lamp is turned off. 
The lamp can also turn off automatically for auto-self protection after lighting for 30 minutes. 
Brightness of the lamp can be adjusted by Flash Output Controller (4). 

Buzz Function

Buzz function can be set by the buzz button (7) and it is turned on when the buzz 
indicator (12) is on; it is shut off when the buzz indicator (12) is off. A beep sound 
will be heard whenit is fully charged and ready to fire.

Model

Flash Output
Guide Number (m ISO 100)
Color Temperature
Power Voltage
Flash Power Control
Modeling Lamp
Recharging Time
Flash Triggering Method
Flash Duration
Fuse
Dimension
Weight

FQS-180

         

 180WS
     44

                              5600±200K
             220V/50Hz or 100V~120V/60Hz
                                 8 steps
                                   75W

0 5~2sec

                 Sync cord, Test button, Slave
                            1/2000-1/800s
                                    5A                         
                         230*200*108MM
                           Approx.1.16KG

                             

.

Shut down the device immediately when it works abnormally and find out the reason.

Do not keep long time in using the modeling lamp. It's better to be cooled 
down for one minute after five minutes continuous use. 

Technical Data

Maintenance

05

06

Avoid sudden impacts and the lamp should be dedusted usually.
It's normal for lamp being warm when in use. Avoid continuous flashes when it is not 
necessary.

Except that users can replace the plug-in tube and modeling lamp by themselves, 
maintenance of all the flashes is up to our authorized maintenance department which 
can provide original accessories. 
One year warranty period will be canceled when any unauthorized maintenance is found.

Disconnect the power when doing maintenance work or cleaning.

New changes made to the specification may not be updated in this manual.the reason.

If the product had failures or is wetted, it can be continuously used only after it is 
repaired by professionals. 

Tube Replacement

Turn down the power before replacing the flash tube and wear insulated gloves. Then, loosen 
the iron wire on the tube, keep a balanced hold on the two feet of the flash tube and pull out 
the old tube gently. Take down the feet casing to put it on the new one. Hold two feet of the 
new tube, and target directly towards the two copper outlets, then push them slightly in. 
Tighten the iron wire to fix the flash tube.