- 26 -
- 27 -
Important Note:
Reattach the grease filter after cleaning and
maintenance of the range hood. Do not operate
the appliance without the grease filter, as it may
cause safety hazards.
Caution:
Risk of demager due to corrosion.
• Always switch on the appliance while cooking
to avoid condensation. Condensate can
produce corrosion damage.
• Surface damage due to incorrect cleaning.
Clean stainless steel surfaces in the direction
of the grain only. Do not use any stainless
steel cleaners for operator controls.
• Surface damage due to strong or abrasive
cleaning agents.
• Replace faulty LED lights to prevent the
remaining lights form overloading.
Warning:
• The range hood should only be cleaned as
instructed; otherwise, it may ignite.
• Please remember not to wet the motor and/or
the control panel, as it may result in damaging
the electric circuits or potential hazards.
• Do not clean the appliance with chemical
agents, such as gasoline, acids, benzene and
solvents.
Risk of Electric Shock:
• Penetrating moisture may result in an electric
shock. Prior to cleaning and maintenance,
pull out the mains plug or switch off the circuit
breaker in the fuse box.
• Do not use any high-pressure cleaners or
steam cleaners, which can result in an electric
shock.
CLEANING AND MAINTENANCE
automatically, the fan will start up, the LOW-
SETTING indicator will fully illuminate, and the
range hood will be operated on low-setting;
press the LOW-SETTING FAN lightly again,
the motor will stop, and the LOW-SETTING
indicator will return to low illumination.
(6)
LIGHTING: The LIGHTING button opens
the smoke baffle plate and turns on the
lights. Once pressed, the
button will fully
illuminate. Press the button again and the light
will turn off and the
LIGHTING indicator will
return to low illumination.
(7)
DELAY: Press the key lightly while the
range hood motor is working, the
delay
indicator will fully illumination, and a two-minute
delay is activated; 2 minutes later, all functions
will turn off, the smoke baffle plate will be
closed automatically, and the range hood will
turn off.
During the delay, if you press the DELAY
button lightly once, the
delay will be
stopped, the delay indicator will return to low
illumination, and the range hood will remain the
current working state.
Lightly press the any control panel button other
than the DELAY button once during the delay
to exit the delay, the
DELAY indicator will
return to low illumination, and the function of
the pressed button operates.
When the range hood is not working, the
DELAY button
is not working, and if the
button is pressed, an alarm sound will engage.
(8) LOCK SCREEN button: Once pressed and
held for 2 seconds when the range hood
fan is not operating, you will hear a “beep”
sound, the
LOCK SCREEN button will
fully illuminate, all buttons will be locked, and
any pressing will be invalid; in order to unlock
the control panel, you must press and hold
the LOCK SCREEN button
for another
2 seconds. When the range hood fan is in
operation, the LOCK SCREEN button is not
working, if the button is pressed, an alarm
sound will engage.
Hints:
1. The range hood will be turned off automatically
other buttons on the control panel will display
low illumination. Lightly press the POWER
button again to turn off the range hood in the
working conditions. Once the range hood is
off, all functions are off, all buttons will cease
to illuminate, and the smoke baffle plate will be
closed automatically.
With the exception of the LOCK SCREEN
button, the other buttons will only work when
the POWER button is active.
(3) HIGH-SETTING/SUPER-HIGH-SETTING
FAN: Lightly press the button, the smoke baffle
plate will open automatically, and the fan will
start up, while the HIGH-SETTING/SUPER-
HIGH-SETTING indicator will fully illuminate
and the range hood will be operated on high-
setting; press the HIGH-SETTING/SUPER-
HIGH-SETTING FAN
lightly again, the
motor will stop, and the HIGH-SETTING/
SUPER-HIGH-SETTING FAN indicator will
return to low illumination; press the HIGH-
SETTING/SUPER-HIGH-SETTING FAN and
hold for 2s, the HIGH-SETTING/SUPER-
HIGH-SETTING indicator will fully illuminate
in green, and the range hood is operated on
SUPER-HIGH-SETTING;Press the HIGH-
SETTING/SUPER-HIGH-SETTING FAN
again and hold for 2s, the range hood can be
operated on the HIGH-SETTING and the
HIGH-SETTING/SUPER-HIGH-SETTING
indicator will fully illuminate; lightly press the
HIGH-SETTING/SUPER-HIGH-SETTING FAN
again, the motor will stop, and the HIGH-
SETTING/SUPER-HIGH-SETTING indicator
will return to low illumination.
(4)
MEDIUM-SETTING FAN: Press the
MEDIUM-SETTING FAN lightly, the smoke
baffle plate will open automatically and the fan
will start up; while the
MEDIUM-SETTING
indicator will fully illuminate, the range hood
is operated on medium-setting;press the
MEDIUM-SETTING FAN
lightly again, the
motor will stop, and the MEDIUM-SETTING
indicator will return to low illumination.
(5)
LOW-SETTING FAN: Press the button
lightly, the smoke baffle plate will open
Operation
1. Fotile Range Hood Control Panel
(1)GESTURE function: Wave hands
quickly
through the sensor windows at two sides, the
smoke baffle plate will automatically open, the
range hood is operated on high-setting and
the lights will be turned on; wave hands
quickly through the sensor windows at two
sides again, all functions of range hood will
be turned off, the button indicator will be
turned off, the smoke baffle plate will be
closed automatically and the range hood is
off.When switching off, press
Lighting and
Medium-setting Fan at the same time for 5
seconds to turn on/off the GESTURE function.
(2)
POWER button: Once you press the
POWER button, the range hood will be
activated, the button will fully illuminate and the
2. Operation Procedure
Power
Sensor
Window
Lock
Screen
Delay Lighting
High-setting/
Super-high-
setting Fan
Medium-
setting
Fan
Low-
setting
Fan
Sensor
Window
Max static pressure 540 Pa
Caution:
1. dB noise in the above table complies with the IEC60704
standard, it is the sound pressure level, the corresponding
sound power level is: 70.5dB(A) for supper-high-setting,
68dB(A) for high-setting, 62.2dB(A) for medium-setting
and 52.5dB(A) for low-setting.
2. The noise --Sones -- in the above table is tested in accordance
with HVI-915-2015 in HVI-accredited laboratories in
American.
3. Such parameters as noise may have a deviation of less
than 5%.
HVI-2100 CERTIFIED RATINGS comply with
new testing technologies and procedures prescribed
by the Home Ventilating Institute, for off-the-shelf
products, as they are available to consumers.
Product
performance is rated at 0.1 in. static pressure, based
on tests conducted in a state-of-the-art test laboratory.
Sones are a measure of humanly-perceived loudness,
based on laboratory measurements.
if it is not operated for 2 minutes in the standby
state;
2. It’s suggested that the range hood be turned
on during steaming to keep the kitchen air
fresh, otherwise, too much steam passing by
the Sensor Window may trigger the GESTURE
function.