FORM 8230 

 

ISSUE DATE: 5/2021       

ECO 1-7727                REV. LEVEL: --             Page 3 of 3 

POTENTIOMETER MOUNTING

ENCLOSURE MOUNTING

•  Remove knock out in front cover. Install potentiometer as shown.

WARNING:

 Potentiometer terminals are at line voltage. Disconnect power at main breaker before servicing.

REMOTE MOUNTING

•  Install potentiometer as shown. Mount to a standard 2” x 4” electrical box. 

NOTE: Extension wire must be rated for line voltage 18AWG min., maximum 100 feet in length. 

WARNING:

 Potentiometer terminals are at line voltage. Disconnect power at main breaker before servicing.

MAINTENANCE

•  The VHC should be cleaned of any accumulated dust or dirt with a vaccum cleaner attachment.

•  The wiring connections should also be checked yearly to maintain a secure connection. 

DISCONNECT POWER BEFORE PERFORMING ANY SERVICE TO THE VHC CONTROL.