background image

 
 
 
 

Issue Date: 7-21-03       Rev. Date: 9-15-03       Rev. Level: 03       ECN: GP-5005       OIPM P/N: 3420367       

Page 5 of 7

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Wiring Diagram 

CH-46 and CH-57 - 

 

Direct Wire Models 

L1

 

 

 

 

 

L2

 

 

 

 

 

Grd

 

 

 

  WIRING

FIELD HARD-WIRING CONVERSION

Some OCH models are factory-equipped with a cordset 
for portability.  You may decide to remove the cordset 
and wire the heater into a permanent location.  Follow the 
steps below to complete this conversion. 
 

1.  Remove junction box cover and keep all screws 

and gaskets. 

2.  Remove wire nuts from black and white leads of 

cordset. 

3.  Remove ground screw that secures the ground 

lead from the cordset. 

4.  Loosen strain relief fitting, remove cordset and 

strain relief fittings from inside and outside the  
box. 

5.  Use ½ inch conduit fittings and conduit for 

permanent installation. 

6.  Fasten field ground wire to the ground screw and 

assure tight connection. 

7.  Terminate L1 and L2 field wires to the power 

wires of the heater with the wire nuts. 

8.  Replace box cover assuring that the gasket is in 

place.  

The gasket must be replaced to maintain 

the outdoor rating of the heater. 

  

L1, L2 and GRD from supplied cordset or 

direct-wired from power supply. 

Hi-temp. wires

INTERNAL WIRING DIAGRAM

OCH heaters are equipped with two 12 gauge hi-
temperature silicone lead wires and a ground 
termination.  For field wiring, use 12 ga. 90º C rated 
wire and connect to the two lead wires in the junction 
box with wire nuts.  Make sure ground wire is properly 
connected to the fixture’s ground terminal located in the 
junction box. 

 

 
 
 

 
 

 

Make certain the power source conforms to 
specifications on the heater label. 
 
Do not depend on a thermostat or other switch 
as the sole means of disconnecting power when 
installing or servicing heater.  Always unplug 
the cordset or open the safety switch and lock it 
open. 
 
All wiring must be performed by a licensed 
electrician. 
 
The cordsets supplied with these heaters are 
equipped with provisions for proper grounding.  
Always mate the cordset plug with the proper 
grounded receptacle in accordance with the 
National Electric Code and all governing local 
codes and ordinances. 
 
Use only copper wire to power these heaters. 
 
Do not use an extension cord to provide power 
to these heaters. 
 
Never connect the green or green-yellow wire to 
a live or “hot” conductor. 

ELECTRICAL SHOCK 
HAZARD 

 

• 

Serious injury or death 
may occur. 

 

• 

Disconnect from electrical 
supply before installing or 
servicing this heater. 

 

• 

Read and follow all safety 
information in box below. 

Summary of Contents for OCH–46-120V

Page 1: ...N GP 5005 OIPM P N 3420367 Page 1 of 7 IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference CONTENTS Specifications Page 2 Tube Installation Page 3 Heater Installation Page 3 4 Wiring Page 5 Replacement Parts Page 6 ...

Page 2: ...ion box adds 2 384 to Dim A Model P N Tube P N Watts Volts Amps Cordset Dim A Dim B Dim C OCH 46 120V 04804402 04432302 1500 120 12 5 YES 42 0 5 375 6 500 OCH 46 208V 04804502 04418102 2000 208 9 6 42 0 5 375 6 500 OCH 46 240V 04804602 04418002 2000 240 8 3 YES 42 0 5 375 6 500 OCH 46 277V 04804702 04419302 2000 277 7 2 NO 42 0 5 375 6 500 OCH 46 120V SS 04805202 04432302 1500 120 12 5 YES 42 0 5 ...

Page 3: ...tubes are horizontal Failure to do this may cause the heating element within the tube to sag and cause premature burnout ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before installing or servicing this heater HEATER INSTALLATION These heaters MUST be installed as follows 12 inches minimum from a vertical surface 24 inches minimum from ANY combustible ...

Page 4: ...is shipped complete with hardware for overhead suspension in two different ways 1 In the hardware bag shipped with your heater you will find two adjustable mounting brackets and fastening screws that should be assembled as shown in figure 1 Once assembled to the heater and mounted these brackets enable the heater to be angled in 15 degree increments up to 45 degrees The mounting centers for the br...

Page 5: ...upply Hi temp wires INTERNAL WIRING DIAGRAM OCH heaters are equipped with two 12 gauge hi temperature silicone lead wires and a ground termination For field wiring use 12 ga 90º C rated wire and connect to the two lead wires in the junction box with wire nuts Make sure ground wire is properly connected to the fixture s ground terminal located in the junction box Make certain the power source confo...

Page 6: ...RIPTION 1 1 SEE HOUSING TABLE HOUSING 2 1 8561700 COVER JUNCTION BOX 3 1 8561400 8560300 WIRE CHANNEL OCH 46 series WIRE CHANNEL OCH 57 series 4 1 3104600 JUNCTION BOX 5 1 SEE CORDSET TABLE CORDSET STRAIN RELIEF not shown 6 2 8561200 END CAP 7 10 2326500 SCR HWHS 8 32 x 3 8 8 1 8521500 NIPPLE CHASE not shown 9 1 8500739 SPACER not shown 10 1 8561800 8560400 REFLECTOR OCH 46 series REFLECTOR OCH 57...

Page 7: ...ocation as the company may designate This warranty does not obligate Fostoria Industries Inc to bear the cost of labor in replacing any assembly unit or component part thereof nor does the company assume any liability for secondary charges expenses for installing or removal or any other consequential losses The company s maximum liability shall not in any case exceed the list price for the product...

Reviews: