background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  SPECIFICATIONS

 
 

 
 

Voltage Cordset 

Plugs  Matching 

Receptacle 

120V 

NEMA 5-15P 

NEMA 5-15R 

240V 

NEMA 6-15P 

NEMA 6-15R 

EXPLOSION HAZARD 

FIRE HAZARD 

 

• 

Serious injury or death 
may occur 

 

• 

Do not use in locations 
containing hazardous 
atmospheres. 

 

DESCRIPTION 

Housing 

24 ga. galv. or stainless steel (SS) 

Finish 

Hi temp. brown enamel paint 

Reflectors, end 
caps 

.032” anodized coilzak aluminum 

Suspension 

Bracket or chain  

U.L. file 
number 

E32304 

SPECIFICATIONS 

Fostoria multi-purpose OCH series electric infrared 
heaters are designed to provide efficient spot heating 
for many commercial and industrial applications.  All 
models operate with a single quartz tube emitter 
included with the heater, are easily installed, and are 
equipped with spectral reflectors for excellent radiant 
output.  They are built with corrosion-resistant 
materials and are 

U.L. listed

 for both 

INDOOR AND 

OUTDOOR applications in the USA and Canada.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Issue Date: 7-21-03       Rev. Date: 9-15-03       Rev. Level: 03       ECN: GP-5005       OIPM P/N: 3420367       

Page 2 of 7

 

 

Junction box adds 2.384” to Dim A. 

Model 

P/N 

Tube P/N 

Watts 

Volts 

Amps 

Cordset  Dim A* 

Dim B

Dim C

OCH–46-120V 

04804402 

04432302 

1500 

120 

12.5 

YES 

42.0” 

5.375”

6.500” 

OCH–46-208V 

04804502 

04418102 

2000 

208 

9.6 

** 

42.0” 

5.375”

6.500” 

OCH–46-240V 

04804602 

04418002 

2000 

240 

8.3 

YES 

42.0” 

5.375”

6.500” 

OCH–46-277V 

04804702 

04419302 

2000 

277 

7.2 

NO 

42.0” 

5.375”

6.500” 

OCH–46-120V-SS 

04805202 

04432302 

1500 

120 

12.5 

YES 

42.0” 

5.375”

6.500” 

OCH–46-208V-SS 

04805302 

04418102 

2000 

208 

9.6 

** 

42.0” 

5.375”

6.500” 

OCH–46-240V-SS 

04805402 

04418002 

2000 

240 

8.3 

YES 

42.0” 

5.375”

6.500” 

OCH–46-277V-SS 

04805502 

04419302 

2000 

277 

7.2 

NO 

42.0” 

5.375”

6.500” 

OCH-57-208V 

04804902 

04416602 

3000 

208 

14.4 

** 

53.0” 

5.375”

6.500” 

OCH-57-240V 

04804802 

04414702 

3000 

240 

12.5 

YES 

53.0” 

5.375”

6.500” 

OCH-57-277V 

04805002 

04419402 

3000 

277 

10.8 

NO 

53.0” 

5.375”

6.500” 

OCH-57-480V 

04805102 

04419502 

2250 

480 

4.7 

NO 

53.0” 

5.375”

6.500” 

OCH-57-208V-SS 

04805702 

04416602 

3000 

208 

14.4 

** 

53.0” 

5.375”

6.500” 

OCH-57-240V-SS 

04805602 

04414702 

3000 

240 

12.5 

YES 

53.0” 

5.375”

6.500” 

OCH-57-277V-SS 

04805802 

04419402 

3000 

277 

10.8 

NO 

53.0” 

5.375”

6.500” 

OCH-57-480V-SS 

04805902 

04419502 

2250 

480 

4.7 

NO 

53.0” 

5.375”

6.500” 

 

**

 208 Volt Models are supplied with a 6 ft cord only (no plug)

A

Summary of Contents for OCH–46-120V

Page 1: ...N GP 5005 OIPM P N 3420367 Page 1 of 7 IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference CONTENTS Specifications Page 2 Tube Installation Page 3 Heater Installation Page 3 4 Wiring Page 5 Replacement Parts Page 6 ...

Page 2: ...ion box adds 2 384 to Dim A Model P N Tube P N Watts Volts Amps Cordset Dim A Dim B Dim C OCH 46 120V 04804402 04432302 1500 120 12 5 YES 42 0 5 375 6 500 OCH 46 208V 04804502 04418102 2000 208 9 6 42 0 5 375 6 500 OCH 46 240V 04804602 04418002 2000 240 8 3 YES 42 0 5 375 6 500 OCH 46 277V 04804702 04419302 2000 277 7 2 NO 42 0 5 375 6 500 OCH 46 120V SS 04805202 04432302 1500 120 12 5 YES 42 0 5 ...

Page 3: ...tubes are horizontal Failure to do this may cause the heating element within the tube to sag and cause premature burnout ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before installing or servicing this heater HEATER INSTALLATION These heaters MUST be installed as follows 12 inches minimum from a vertical surface 24 inches minimum from ANY combustible ...

Page 4: ...is shipped complete with hardware for overhead suspension in two different ways 1 In the hardware bag shipped with your heater you will find two adjustable mounting brackets and fastening screws that should be assembled as shown in figure 1 Once assembled to the heater and mounted these brackets enable the heater to be angled in 15 degree increments up to 45 degrees The mounting centers for the br...

Page 5: ...upply Hi temp wires INTERNAL WIRING DIAGRAM OCH heaters are equipped with two 12 gauge hi temperature silicone lead wires and a ground termination For field wiring use 12 ga 90º C rated wire and connect to the two lead wires in the junction box with wire nuts Make sure ground wire is properly connected to the fixture s ground terminal located in the junction box Make certain the power source confo...

Page 6: ...RIPTION 1 1 SEE HOUSING TABLE HOUSING 2 1 8561700 COVER JUNCTION BOX 3 1 8561400 8560300 WIRE CHANNEL OCH 46 series WIRE CHANNEL OCH 57 series 4 1 3104600 JUNCTION BOX 5 1 SEE CORDSET TABLE CORDSET STRAIN RELIEF not shown 6 2 8561200 END CAP 7 10 2326500 SCR HWHS 8 32 x 3 8 8 1 8521500 NIPPLE CHASE not shown 9 1 8500739 SPACER not shown 10 1 8561800 8560400 REFLECTOR OCH 46 series REFLECTOR OCH 57...

Page 7: ...ocation as the company may designate This warranty does not obligate Fostoria Industries Inc to bear the cost of labor in replacing any assembly unit or component part thereof nor does the company assume any liability for secondary charges expenses for installing or removal or any other consequential losses The company s maximum liability shall not in any case exceed the list price for the product...

Reviews: