background image

Installation instructions 

The installation must be carried out by a specialized technician.  
The installer must respect the local norms  and standards in use. 

Installation: 

  The  worktop  or  support  on  which  the  hob  is  installed,  along  with  all  the  materials 

installed must be able to resist to temperatures of up to 100 °C. 

  The nearby walls and edges must also be able to resist to high temperatures. 

  The hobs  are  classified  as  “Y”  class for heat  protection.  Ideally  the  hob  should  be 

installed with plenty of side space on either side to allow air circulation. 

In the case 

of a rear and side wall make sure the opposite sides are clear from any wall,  
unit  or  divider,  mobile  or  immobile, with  a  height  superior  to  the  installation 
surface of the cooker hob. 

  Ensure that there is a distance of 50 mm between the hob and the wall or edges. 

  Some  materials  which  are  often  used  to  make  worktops  tend  to  expand  when  in 

contact  with  water.    Attention  must  be  used  for  the  installation  of  the  gasket 
supplied  with  the  apparatus.  The  main  function  of  these  gasket  is  to  prevent  that 
spilled  liquids  flow  to  the  below  cabinets.    This  gaskets  guarantees  the  maximum 
protection in combination with a smooth work tops.  

  The safety gap between the hob and the cooker hood placed above the apparatus  

must  respect  the  indications  of  the  hood  manufacturer.  In  case  of  absence  of 
instructions please maintain a minimum distance of 650 mm.  

  The connection cords should be not be tense or subject to solicitation or friction, for 

example near a drawer.  

 

CONNEXION OF THE DIFFERENT ELEMENTS 

The  installation  of this  appliance and  the  connections  of  the  electrical  network  should  be 
carried out  by a specialised technician in respect with the local norms  and standards in 
use. 

Connection of cooking zones 

Each connector of each cooking zone, is identified  by a sticker with  a number  from  
5 to 8 which corresponds to the following: 
 

 

5: Heating zone 1100 W / Glass diameter 270mm (code 736127*) 

 

7: Heating zone 2300 W / Glass diameter 300mm (code 736230*) 

 

8: Heating zone 2300 W / Glass diameter 350mm (codice 736335*) 

 

The control panel is identified  with the letter “C” on the connector 

 

On the junction  box, you can find the female connectors with the corresponding units: 

5-6-

7-8-C

 
 
 

 

Summary of Contents for NFI 6930

Page 1: ...MANUALE MANUTENZIONE Installation instructions Notice d installation Montageanweisungen Instrucciones de instalaci n...

Page 2: ...N 4 INSTALLATION 4 VENTILATION 5 INSTALLATION INSTRUCTIONS 6 CONNEXION OF THE DIFFERENT ELEMENTS 6 CONNECTION OF THE COOKING ZONES 6 COMBINATION OF THE COOKING ZONES 6 INITIAL CONFIGURATION PROCEDURE...

Page 3: ...ct code Color N Zones Length mm A Width mm Radius mm Cut out for Flushmount Border mm B Cut out Depth mm D Thickness glass mm Cut out for Flushmount Border mm C Cut out for Q4 border mm Tot Thickness...

Page 4: ...73 69 040 270 x 210 x 48 mm 4 7400 MULTIZONES INSTALLATION Installation Unpack all the materials The installation and connection of the appliance have to be carried out by an approved specialists The...

Page 5: ...be used The appliance cannot be installed above a dishwasher or dryer The steam may damage the electronic appliances If the appliance is installed above an oven this must have a cooling fan Furthermor...

Page 6: ...he main function of these gasket is to prevent that spilled liquids flow to the below cabinets This gaskets guarantees the maximum protection in combination with a smooth work tops The safety gap betw...

Page 7: ...not take manual and or safe r cables show the number for the correc elow example 4 zones Connect the hea e junction box trol panel to the C plug of the junction bo oking zones uct code 7369030 inducti...

Page 8: ...then push and hold button 1 for few seconds until the blinking E symbols appear 5 Wait until E symbols stop blinking 6 After few seconds E will automatically become C confirming that the previous con...

Page 9: ...n Caution This appliance must only be connected to an electric network of 230 V 50 60 Hz Always ground the plug Respect the connection diagram The terminal is located at the back of the apparatus box...

Page 10: ...l 1 and the Phase L2 to the terminal 2 Caution Make sure to have carefully secured the cables and jumpers and tightened the screws We cannot be held responsible for any incident resulting from the inc...

Reviews: