background image

DESCRIPTION OF THE APPLIANCE 

Touch Control Panel

 

                    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions of the control panel and cut out: 

 

Induction Plates:

 

 
 
 
 
 
 
 
 
 

 

 
Dimensions of the Induction Plates and cut out: 

Product code  

Color 
 

N°  
Zones 
 

Length 
  (mm) 
      A 

Width 
 (mm) 
 

Radius 
 (mm) 
 

Cut out for 
Flushmount 
Border (mm) 
        B 

Cut out 
  Depth 
   (mm) 
       D 

Thickness  
glass (mm) 
 

Cut out for 
Flushmount 
Border (mm) 
        C 

 Cut out for  
Q4  border 
    (mm) 
 

Tot.  
Thickness 
  (mm) 
 

73 68 030 
 

Black 

   275 

  150 

  75 

 
 
 
279 x 154  
     R77  
 

 

     5 

      4 

 
265 x 140  
    R70 

 
190 x 120 
 

     37 

73 68 040 

73 68 035 

White 

73 68 045 

  EXAMPLE OF FLUSHMOUNT

 

 

  EXAMPLE OF FLUSHMOUNT

 

 

Summary of Contents for NFI 6930

Page 1: ...MANUALE MANUTENZIONE Installation instructions Notice d installation Montageanweisungen Instrucciones de instalaci n...

Page 2: ...N 4 INSTALLATION 4 VENTILATION 5 INSTALLATION INSTRUCTIONS 6 CONNEXION OF THE DIFFERENT ELEMENTS 6 CONNECTION OF THE COOKING ZONES 6 COMBINATION OF THE COOKING ZONES 6 INITIAL CONFIGURATION PROCEDURE...

Page 3: ...ct code Color N Zones Length mm A Width mm Radius mm Cut out for Flushmount Border mm B Cut out Depth mm D Thickness glass mm Cut out for Flushmount Border mm C Cut out for Q4 border mm Tot Thickness...

Page 4: ...73 69 040 270 x 210 x 48 mm 4 7400 MULTIZONES INSTALLATION Installation Unpack all the materials The installation and connection of the appliance have to be carried out by an approved specialists The...

Page 5: ...be used The appliance cannot be installed above a dishwasher or dryer The steam may damage the electronic appliances If the appliance is installed above an oven this must have a cooling fan Furthermor...

Page 6: ...he main function of these gasket is to prevent that spilled liquids flow to the below cabinets This gaskets guarantees the maximum protection in combination with a smooth work tops The safety gap betw...

Page 7: ...not take manual and or safe r cables show the number for the correc elow example 4 zones Connect the hea e junction box trol panel to the C plug of the junction bo oking zones uct code 7369030 inducti...

Page 8: ...then push and hold button 1 for few seconds until the blinking E symbols appear 5 Wait until E symbols stop blinking 6 After few seconds E will automatically become C confirming that the previous con...

Page 9: ...n Caution This appliance must only be connected to an electric network of 230 V 50 60 Hz Always ground the plug Respect the connection diagram The terminal is located at the back of the apparatus box...

Page 10: ...l 1 and the Phase L2 to the terminal 2 Caution Make sure to have carefully secured the cables and jumpers and tightened the screws We cannot be held responsible for any incident resulting from the inc...

Reviews: