installation
WARNING!
Electrical Shock Hazard
Disconnect power before servicing.
Use 10 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Electrical Connection
The cooktop is equipped with a flexible metal conduit encasing 3 wires ready for
connection to a grounded power supply.
Please note the nameplate label located below the cooktop
1. Disconnect power.
2. Remove junction box cover if it is
present.
3. Connect the flexible cable conduit from
the cooktop to the junction box using
a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if
present.
5. See next page to complete installation for your type of electrical connection.
208/240 V, 60 Hz, 50 A fuse rating
Black wire: connect to L1 (hot)
Red wire: connect to L2 (hot)
Green/Yellow wire: connect to GND
(ground)
A dedicated line and junction box should
be used to connect the cooktop to a
50
A
circuit.
L1 (black)
L2 (red)
GND (green/yellow)
UL listed or CSA
approved conduit
connector
Nameplate
ENGLISH
27