7

3LIOU2FO

hood and to make you familiar with its use. 

Since these instructions cover more than one 

type of hood within the same series, it may 

be that reference is made to components that 

do not form part of the hood that you  are 

installing. The hood should be used in the 

exhaust version to discharge all the kitchen 

vapours and odours out-door of the building. 

Fittings can vary from  country to country. 

We reserve  the right to modify the product 

without any notice always with  the aim of 

improvements and in compliance with the 

relevant norms.

 

 

SUGGESTIONS FOR USING THE HOOD IN 

EXHAUST POSITION

                                                                                                

When an exhaust hood and a heat source 

requiring ambient air (e.g. gas, oil, coal stoves, 

etc.) are used at the same time, attention 

is required because the air necessary  for 

combustion is exhausted from the room through 

the hood and this creates depression. There is 

no such danger when the maximum depression 

in the room is 0,04 mbar. In this condition no 

exhaust gas from the heat source is piped. 

To assure this condition, make opening in the 

room which cannot be closed (doors, windows, 

etc. are insufficient) and through which the air 

necessary for combustion can freely flow.

Note : All the exhaust ductwork in the 

apartment or house should be studied. In 

case of doubts, get advice or authorization 

from the person or agency responsible for 

the building.

Note : The efficiency of the exhaust hood 

decreases as the length of the ducts and 

number of increase. When using the exhaust 

version, follow these rules : Do not connect 

the exhaust hood to chimneys, flues, and 

air ducts serving the room. Before venting 

into exhaust flues and ducts no longer in 

use, ask for approval of person or agency 

responsable for the building. The evacuated 

air must not be let into a warm airduct. For 

the evacuation of the exhausted air please 

note official instructions. 

INSTALLATION       

                                                                              

Warning :

The discharge air is to be directed to 

building exterior.

The hood must be mounted over the centre of 

cooking area. The minimum distances between 

the cooking area and the underside of the hood 

are 650 mm (25”19/32).

Warning : If the room contains a flued 

fuel burning appliance which is not of the 

balance flue type make sure these is an 

adeguate air inlet to the room at all times so 

EN

IMPORTANT SAFETY INSTRUCTIONS   

                                           

Carefully read the following important information 

regarding installation safety and maintenance. 

READ AND SAVE THESE INSTRUCTIONS 

for future reference.
REQUIREMENTS

120V, 60 Hz. 15A Circuit grounding.

INTENDED FOR DOMESTIC COOKING ONLY !

SAFETY MEASURES                                                             

- Do not connect the exhaust hood to the 

chimneys, flues and airducting the room.

- The evacuated air must not be let into a warm 

air duct.

- This appliance must be connected to a system 

equipped with earth or ground plate.

- When performing maintenance operations, 

disconnect the appliance from the field 

connection.

- Do not do any flambè cooking underneath the 

hood - When frying, never leave the pan alone 

because the cooking oil could flare up.

- Clean all the surfaces frequently to avoid 

danger of fire. To do so use a cloth and or 

brush soaked in denatured ethyl alcohol. It also 

important  to remove and clean or substitute 

frequently the filter installed in the hood.

- It advisable to utilise cooking surfaces of the 

same width  as the hood.

- Do not operate with a damaged cord or plug. 

Discard fan or return to an authorized service 

facility for examination and/or repair.

- Do not run cord under carpeting. Do not cover 

with throw rugs, runners or similar coverings. 

Arrange cord away from traffic area and where 

it will not be tripped over. 

- Do not route cord under furniture or 

appliances.

- Do not operate any fan with a damaged cord 

or plug. Discard fan or return to an authorized 

service facility for examination and/or repair. Do 

not run cord under carpeting.

- Wiring shall be protected from sharp edges 

(including male screw threads), burrs, fins, 

moving parts, and other agencies that might 

abrade the insulation on conductors.

The device has a switch for disconnection from 

the main electricity network, which is placed 

inside the hood immediately after the filter and is 

of red colour. 

By placing the knob in the Off position, the mo-

tor is not activated while the lamp can operate 

normally.

INTRODUCTION     

                                                                                         

These instructions are designed to tell you of 

the various technical details of your cooker 

USER INSTRUCTIONS

Summary of Contents for 2462900

Page 1: ...CHIMNEY HOOD Installations instructions EN FR HOTTE DE CUISINE Instructions pour le montage 2462900 CUNEO HOOD 30 2462910 CUNEO HOOD 36...

Page 2: ...2 3LIOU2FO 1 37 64 30 36 12 1 32 10 1 8 19 53 64 25 19 32 29 17 32 Fig 1 Fig 2...

Page 3: ...3 3LIOU2FO A B C D E F G H 30 36 12 23 8 31 32 6 7 16 1 25 32 1 25 32 8 29 32 8 29 32 2 23 64 2 23 64 6 7 64 9 1 16 12 63 64 12 63 64 MODELS A B C D E F G H Fig 3 Fig 4...

Page 4: ...4 3LIOU2FO Step 1 Step 2 Step 3 Fig 5...

Page 5: ...5 3LIOU2FO Step 1 Step 2 Step 3 Fig 6...

Page 6: ...6 3LIOU2FO 1 3 2 3 4 Fig 9 Fig 10 Fig 7 1 3 2 3 4 Fig 7...

Page 7: ...mm 25 19 32 Warning If the room contains a flued fuel burning appliance which is not of the balance flue type make sure these is an adeguate air inlet to the room at all times so EN IMPORTANT SAFETY I...

Page 8: ...e power supply cord must be replaced by the service WARNING GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric sh...

Page 9: ...uzette cherries jubilee peppercorn beef flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropiate for t...

Page 10: ...l wiring and other hidden utilities d Ducted fans must always be vented to the outdoors e If this unit to be installed over a tube or shower it must be marked as appropriate for the application and be...

Page 11: ...11 3LIOU2FO...

Page 12: ...e La hotte doit tre mont au centre de la zone CONSIGNES DE S CURIT IMPORTANTES Lisez attentivement les suivantes informations importantes concernant la s curit d installation et d entretien LIRE ET CO...

Page 13: ...ordon d alimentation l appareil doit tre plac de sorte que la prise soit accessible Attention Si il ya trois fils dans le c ble d alimentation lectrique ils doivent tre connect s comme suit Gris Jaune...

Page 14: ...fait de severallayers de cet alliage en en le frappant ou crasant Le filtre en aluminium peut changer de couleur qui n aura pas d influence sur l efficacit du filtre REMPLACEMENT OU NETTOYAGE DES FIL...

Page 15: ...vec tous les codes et normes applicables y compris la construction d incendie nominale b Air suffisante est n cessaire pour la combustion et l vacuation compl te des gaz par la chemin e chemin e des q...

Page 16: ...16 3LIOU2FO...

Reviews: