Warnings!

The air outlet of the appliance must not be connected to a flue which is used for 

exhausting

other fumes from appliances, such as a central heating, boilers etc..

For the external exhausting of the fumes, comply with the regulations in force.

Ventilate the room suitably according to the laws in force when the appliance is wor-

king together with gas, oil or coal burning appliances, at the same time.

The motor of the peripheral exhausting group is powered by the cooker-hood placed 

in the kitchen. 

Before connecting the cooker hood to the mains supply, make sure that the voltage 

indicated in the rating plate corresponds to the mains voltage in the home.

Before carrying out any sort of maintenance or cleaning operation, make sure that 

the appliance is disconnected from the electrical mains.

An appropriate maintenance ensures a good working and a good performance in the 

long run. 

Useful warnings:

- Use an air outlet pipe with a maximum length not higher than 5 meters.

- Limit the number of bends in the exhausting pipe as every bend reduces the per-

formance up to one linear meter. (If you use 2 90° bends, than the length of the pipe 

has not to be higher than 3 meters).

- The material for the pipe has to be approved by an authorized company.

-  It  is  important  to  avoid  changes  in  the  diameter  (we  recommend  a  diameter  of 

150mm).

- Read carefully the manual of instructions and installation of the unit.

- Sirius will not be responsible for problems of capacity and/ or noise level due to the 

missed respect of the warnings included in the manual of instructions. 

The electric box cable should not be cut or joined together with other cables, since 

it could compromise the proper working and the safety conditions of the appliance. 

Furthermore, this will invalidate the manufacturer’s warranty coverage.

Summary of Contents for 2459 940

Page 1: ...NED DURING SHIPPING SHIPPING DAMAGE MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR BUILT IN HOODS Models covered by this instruction 2458 900 SU901 BEFORE...

Page 2: ...ommencing in stallation All electrical wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Make sure all existing duct work is clean of grease bu...

Page 3: ...TABLE OF CONTENTS 3 Warnings 4 Useful warnings 4 Types of installation 5 Installation of the appliance 6 Electrical connection of the hood SEM1 6 WARRANTY 7...

Page 4: ...ins An appropriate maintenance ensures a good working and a good performance in the long run Useful warnings Use an air outlet pipe with a maximum length not higher than 5 meters Limit the number of b...

Page 5: ...and connected to the cooker hood which is in the kitchen Types of installation to make the installation easy the appliance can be fixed on the wall on the ceiling or on the floor in a horizontal posit...

Page 6: ...tted extraction motor on the wall by matching the holes of the bra ckets with the plastic dowels Screw with the screws sup plied Connection of the pipes the appliance is endowed with an entrance and a...

Page 7: ...directly during use and or maintenance and which may be subject to wear The formation of rust and stains on the steel due to the use of unsuitable cleaning agents Any functional defect indicated by t...

Page 8: ...in due time by FOSTER with the desire of offering the best service available FOSTER is not liable for any damages direct or indirect caused to people objects and pets for failure to follow all the ins...

Page 9: ...s tension Tout le c blage lectrique doit tre correctement install isol de mise la terre conform ment aux codes et aux normes applicables Assurez vous que les conduits d vacuation sont propres et libre...

Page 10: ...a Longueur du Conduit 4 LECTRICIT 5 Alimentation lectrique 5 UTILISATION 6 INSTALLATION 7 PROC DURES D UTILISATION 9 Fonctions 9 ENTRETIENT 10 Remplacement des Ampoules 10 GARANTIE 12 10 Attention 11...

Page 11: ...nsable Num ro limit de courbes angle maximal de courbure 90 Mat riel approuv aux termes de la loi viter des changements draconiens de section diam tre constant conseill 150 mm Faites attention aux ins...

Page 12: ...ctant la hotte aspirante situ e en cuisine Modalit de fixation pour faciliter les op rations d installation vous pouvez fixer l appareil la paroi au plafond ou sur le sol en position horizontale ou ve...

Page 13: ...a paroi les points o vous ferez les trous Introduisez les goujons fournis dans les trous Appuyez le distributeur contre la paroi en faisant co ncider les trous des triers avec les goujons en plastique...

Page 14: ...14 Connection lectrique L appareil est pourvu d un c ble lectrique de 7 m tres qui doit tre branch au bornier de la hotte qui se trouve dans la bo te en plastique noir...

Page 15: ...et l usure Formation de rouille et taches sur l inox d l utilisation de d tergents pas adaptes Tout d faut fonctionnel indiqu par le client et pas v rifi pendant l examen de la part du technicien Dans...

Page 16: ...st pas responsable pour tout ventuel d g t direct ou indirect caus personnes objets et animaux domestiques cause de l inobservance des instructions contenues dans la notice d utilisation et pour tout...

Reviews: