fos4X Blackbird OECD MDE1185 Instructions For Use Manual Download Page 3

Table of Contents

Table of Contents

1

About this Document......................................................................................... 6

1.1

Target Audience..................................................................................................... 6

1.2 Objective of these Operating Instructions.................................................... 6

1.3 Identification of Information............................................................................. 6

1.3.1

Safety-relevant Information................................................................. 6

1.3.2 Non-safety-related Information.......................................................... 7

1.4 Abbreviations...........................................................................................................7

2

Safety.....................................................................................................................9

2.1 Conformity............................................................................................................... 9

2.2 Changes to the Product......................................................................................9

2.3 Qualification of Personnel..................................................................................9

2.4 Intended Use......................................................................................................... 10

2.5 Residual Risks........................................................................................................10

2.5.1 Explosion Protection.............................................................................. 10

2.5.2 Working Environment Wind Turbine.................................................10

3

Product Description........................................................................................... 11

3.1 Functional Description........................................................................................ 11

3.1.1

Overview......................................................................................................11

3.1.2 Operation....................................................................................................12

3.2 Technical Data.......................................................................................................12

3.2.1 Measurement and Sensors..................................................................12

3.2.2 Interfaces................................................................................................... 14

3.2.3 Optical Data.............................................................................................. 14

3.2.4 Electrical Data.......................................................................................... 15

3.2.5 Environmental Conditions.................................................................... 15

3.2.6 Tested Standards and MTBF............................................................... 16

3.2.7 Mechanical Data..................................................................................... 16

3.2.8 Dimensions................................................................................................ 17

© fos4X 2020

MDE1185_4-10_1.3.x_5.0_Blackbird

OECD_(6CH, ETH)-en-us

3 / 48

Summary of Contents for Blackbird OECD MDE1185

Page 1: ...pe Measuring device Product Version 1 3 x Document Version 5 0 Issue Date 2020 02 07 Language en us INSTRUCTIONS FOR USE Blackbird OECD 6CH ETH MDE1185 Product Type Measuring device Product Version 1...

Page 2: ...Violations will result in the liability for damages All rights reserved in the event of patent utility model or design registration All rights reserved fos4X is a trademark of fos4X GmbH Brand names...

Page 3: ...tion of Personnel 9 2 4 Intended Use 10 2 5 Residual Risks 10 2 5 1 Explosion Protection 10 2 5 2 Working Environment Wind Turbine 10 3 Product Description 11 3 1 Functional Description 11 3 1 1 Overv...

Page 4: ...ge 27 5 Installation 28 5 1 Important Safety Notes for Installation 28 5 2 Attaching the Measuring Device in the Control Cabinet 28 5 3 Connecting the Interfaces 28 5 4 Connecting the Power Supply 29...

Page 5: ...9 2 2 Replacing the PWR Connector 39 9 2 3 Firmware Update 40 9 3 fos4X Support 42 9 4 Spare Parts and Accessories 43 10 Taking out of Service and Disposal 44 10 1 Taking out of Service 44 10 2 Disass...

Page 6: ...afety chapter applies to the entire use of the product See Safety page 9 Safety notes at the beginning of a section apply to the entire section Safety notes before a step apply to the entire following...

Page 7: ...f an instruction List Point 1 Point 2 Enumeration with title Identification of Information page 6 Cross reference Bold Text Highlighting of particularly important information Software text Text parame...

Page 8: ...Max Maximum MTBF Mean Time Between Failures OECD Opto Electronic Converter Device PC Personal Computer SMF Single Mode Fiber UDP User Datagram Protocol 8 48 MDE1185_4 10_1 3 x_5 0_Blackbird OECD_ 6CH...

Page 9: ...rained personnel Personnel trained in the operation and safe use of the product Qualified personnel Personnel who based on their specialist training knowledge and experience and knowledge of the relev...

Page 10: ...Residual Risks 2 5 1 Explosion Protection The product is not suitable for use in potentially explosive environments 2 5 2 Working Environment Wind Turbine The use of the product in wind turbines requi...

Page 11: ...ew TIP Number of channels depends on the variant Figure 1 Overview 1 Mounting plate 2 E 2000 connectors 3 PWR connector 4 Data interfaces The Blackbird OECD consists of the following components Mounti...

Page 12: ...are connected via fiber optical cables to the E 2000 APC connectors of the Blackbird OECD The Blackbird OECD evaluates the signals of the sensors and provides the wavelengths of the individual sensor...

Page 13: ...n Time Protocol 300 s 1 Standard deviation at a sampling frequency of 5 Hz 2 At wavelength 1552 nm and signal level 60 3 Time between power up and operation within specification Requirements for senso...

Page 14: ...or RJ45 Transfer rate 10 100 Mbps Max Output rate 1000 Hz Protocol IPv6 PTP protocol IEEE 1588 PTPv2 3 2 3 Optical Data Table 7 Optical Data Property Value Unit Connector type E 2000 APC Fiber type SM...

Page 15: ...ction class IP20 Maximum operating altitude 3000 m Permitted temperature Transport and storage 40 85 C Permitted relative humidity Non condensing Transport and storage 5 95 Permitted temperature Opera...

Page 16: ...3M6 IEC 60068 2 2 Class 3M6 Electromagnetic Compatibility IEC 61326 1 EN 55032 MTBF Table 11 MTBF Property Value Unit MTBF 100000 h 3 2 7 Mechanical Data Table 12 Mechanical Data Property Value Unit L...

Page 17: ...3 Product Description 3 2 8 Dimensions TIP Number of channels depends on the variant Figure 4 Dimensions front view fos4X 2020 MDE1185_4 10_1 3 x_5 0_Blackbird OECD_ 6CH ETH en us 17 48...

Page 18: ...3 Product Description Figure 5 Dimensions top view 18 48 MDE1185_4 10_1 3 x_5 0_Blackbird OECD_ 6CH ETH en us fos4X 2020...

Page 19: ...e serial number CE marking RoHS marking Indication of the laser class of the product Class 1 Laser Product Power supply 12 24V Power consumption max 15W Optional Device designation KF123 Optional Cust...

Page 20: ...ion On LED is continuously on Slow flashing 1 s Fast flashing 1 s Single flash 1 s Double flash 1 s Triple flash 1 s Quadruple flash 1 s 3 4 1 2 LEDs on the PWR connector There are 2 LEDs on the PWR c...

Page 21: ...n the PWR connector STATUS LED Green Yellow Red On System healthy Measurement warning Measurement error Slow flashing Sytem auto adjust System error Fast flashing Identify System not adjusted TIP The...

Page 22: ...Identify Status is activated by a network command The blink pattern can be used to identify the Blackbird OECD System error Error in the power supply Error in the light source General system error Sy...

Page 23: ...ctions Signal Warning There are one or more warnings See Tab 19 Signal Quality page 23 Measurements are possible The measurements may be inaccurate due to boundary effects and environmental conditions...

Page 24: ...messages Communication takes place via IPv6 link local addresses The fos4X multicast address ff02 13c is used for device recognition For communication via the Ethernet interface fos4X recommends the u...

Page 25: ...ackbird OECD is packed in a box with foam inserts One box contains up to 5Blackbird OECD The box has the dimensions 645 x 492 x 216 mm length x width x heigth 4 3 Unpacking Unpacking the the measuring...

Page 26: ...device in a different packaging 1 Choose a box so that the measuring device with padding material fits into the box 2 Open the box 3 Pack the measuring device in the box with padding material Make su...

Page 27: ...Store the Blackbird OECD in a dry and clean place u Store the Blackbird OECD in a transport packaging See Packing page 26 u Observe the environmental conditions See Environmental Conditions page 15 fo...

Page 28: ...the Control Cabinet Conditions Control cabinet with sufficient space for installation See Dimensions page 17 Control cabinet with permissible environmental conditions See Environmental Conditions pag...

Page 29: ...the MC 1 5 2 GF 3 81 connector to the PWR connector 4 Switch on the power supply 5 5 Connecting a Sensor NOTICE Poor signal quality due to dust and dirt on the sockets and connectors Optical connectio...

Page 30: ...om the socket 4 2 Clean the sockets 4 with an optical connector cleaner See manual of the optical connector cleaner 3 Carefully open the protective cover 3 on the connector 2 4 Clean the connector 2 w...

Page 31: ...ructions See Safety page 9 6 1 Commissioning the Ethernet Interface For communication via the Ethernet interface fos4X recommends the use of the fos4X C API See fos4X C API documentation fos4X 2020 MD...

Page 32: ...7 1 Monitoring Operation In normal operation of the Blackbird OECD no operating actions are necessary u Monitor operation via an interface See Software page 23 In case of errors see Troubleshooting pa...

Page 33: ...tions do not help to fix the problem u Contact fos4X Support See fos4X Support page 42 Table 21 Troubleshooting PWR LEDs Problem Possible cause Solution POWER LED on the PWR connector is not on Blackb...

Page 34: ...ns properly Configuration error u Do a firmware update See Firmware Update page 40 STATUS LED on PWR connector does not light green See LEDs on the PWR connector page 20 System error 1 Check the power...

Page 35: ...range See Measurement and Sensors page 12 u Make sure that only permitted sensors are connected See Measurement and Sensors page 12 Temperature Too Low or Temperature Too High u Make sure to operate...

Page 36: ...supply off and on Calibration Missing u Contact fos4X Support See fos4X Support page 42 No Signal u Make sure that a sensor is connected u Clean the optical connectors See Cleaning E 2000 APC Connecti...

Page 37: ...he Ethernet cable for damage u Check that the Ethernet cable is plugged in Error in the Ethernet network u Check the Ethernet network and configuration No Ethernet connection Blackbird OECD defective...

Page 38: ...nce 9 2 1 Cleaning E 2000 APC Connections Figure 12 E 2000 APC connector and socket 1 Locking mechanism 2 Connector 3 Protective cover 4 Socket 5 Dust cap Table 24 Material and equipment Name Type Qua...

Page 39: ...00 APC connection is cleaned 10 Repeat the procedure for all connections 9 2 2 Replacing the PWR Connector Table 25 Material and equipment Name Type Quantity GTIN Power supply connector MC 1 5 2 GF 3...

Page 40: ...ware fos4X Firmware Flasher f3 exe 1 Conditions Firmware archive for the Blackbird OECD available IPv6 protocol enabled on the PC Doing a firmware update via fos4X Firmware Flasher 1 Stop the normal o...

Page 41: ...correct network adapter is selected c Make sure that the IPv6 protocol is enabled on the PC d Make sure that the PC has a valid IPv6 link local address e Click on in Network Interface 7 Click on in F...

Page 42: ...een check mark Click on FLASH BOOTLOADER FIRMWARE The status of the update is displayed in a new window 13 Wait until the firmware update is complete 14 Disconnect the PC from the Blackbird OECD 15 If...

Page 43: ...Type Manufacturer GTIN Power supply connector MC 1 5 2 GF 3 81 Phoenix Contact 4017918050313 Accessories Table 28 Accessories Name Type Manufacturer GTIN Optical connector cleaner OCC A Ultra Fujikura...

Page 44: ...se the locking mechanism 1 of the connector 2 b Remove the connector 2 from the socket 4 c Attach a dust cap 5 on the socket 4 d Repeat the procedure for all sensors 3 Remove the power cable from the...

Page 45: ...sposal of the product Improper disposal of the product may cause damage to the environment u Observe applicable environmental regulations The Blackbird OECD is an electrical appliance and must not be...

Page 46: ...content 19 Fig 7 LEDs on the PWR connector 21 Fig 8 LED on the Ethernet connector 22 Fig 9 ETH connector 28 Fig 10 PWR connector 29 Fig 11 E 2000 APC connector and socket 30 Fig 12 E 2000 APC connect...

Page 47: ...16 Tab 13 Mounting 16 Tab 14 LED Flashing Patterns 20 Tab 15 POWER LED on the PWR connector 21 Tab 16 STATUS LED on the PWR connector 21 Tab 17 STATUS LED and device state 21 Tab 18 LED on the Ethern...

Page 48: ......

Reviews: