3. Product Description
Signal Quality
Associated status codes
Signal Error
■
Temperature Too Low
■
Temperature Too High
■
Signal Level Too Low
■
Signal Level Too High
■
Wavelength Too Low
■
Wavelength Too High
■
Device Error
■
Adjustment Missing
■
No Signal
■
Device Initializing
3.5.2 Ethernet Interface
In Ethernet mode, the Blackbird OECD transmits the data in the form of UDP
messages.
Communication takes place via IPv6 link-local addresses.
The fos4X multicast address
ff02::13c
is used for device recognition.
For communication via the Ethernet interface, fos4X recommends the use of the
fos4X C API. See fos4X C API documentation.
Time synchronization
In Ethernet mode, the Blackbird OECD synchronizes with a PTP master clock with the
following settings:
■
IEEE1588v2 via UDP via IPv6.
■
Standard profile E2E.
■
Two-Step or One-Step.
■
Multicast-Scope 2 (Link-Local).
■
Domain number 0.
24 / 48
MDE1185_4-10_1.3.x_5.0_Blackbird
OECD_(6CH, ETH)-en-us
© fos4X 2020
Summary of Contents for Blackbird OECD MDE1185