background image

27

11)  Service calls to connect, convert or otherwise repair the electrical wiring and/or gas line to properly use the product.

12) Service calls to provide instructions on the use of a Forza product.

13) Repair or failure of the product if it is abused, misused, used improperly, used for other than the intended purpose or if 

used commercially/industrially.

14) Damage or repairs caused by the use of harsh chemicals or cleaning products improperly applied.

15) Replacement of wear and tear parts.

16) Replacement of house fuses or resetting of circuit breakers.

17) Damages to anything situated next to the product, including, but not limited to, ceiling, floor or cabinetry.

18) Defects and damages arising from accidents, alterations, misuse, abuse, improper installation, or installation that does 

not conform to instructions given by Forza.

19) Damages occurred during transit, handling and/or installation of the product.

20) Defects and damage arising from external forces beyond the control of Forza such as fire, flood, earthquakes and other 

acts of God.

21) Forza cannot guarantee the availability of service in areas more than 30 miles from an authorized retailer. In such cases 

where travel charges are levied, those will be borne by the consumer.

22)  This warranty only covers service performed at the location of product installation and will not cover costs  associated 

with repairing off-site unless expressly authorized by Forza nor does it cover the travel costs associated with providing 
service to remote locations.

23) Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.

24) Products with original serial numbers that have been removed.

25) Replacement light bulbs are not covered by the product warranty.

26) Damages to people or property caused by the product or through its usage.

In the case that the product is will be installed in a remote area, where certified trained technicians are not reasonably available, 
the customer will be responsible for the transportation costs for the delivery of the product to the nearest authorized service 
center or for the travel costs of a certified trained technician.

Remote locations/area: are defined as being outside of a 30 miles from any service provider.

Forza reserves the right to revise this warranty at any time.

Forza does not assume any responsibility for incidental or consequential damages. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply 
to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to 
state.

Summary of Contents for FH3011

Page 1: ...USE INSTALLATION MANUAL Range Hoods FH3011 FH3611 FH3018 FH3618 FH4818 FH3624 FH4824...

Page 2: ...you begin using your new Forza product please take a moment to review the Use Installation Manual You will find the answers to all of your questions as well as some very important safety information...

Page 3: ...imensions and Specifications 10 Preparation for Installation 12 Installation 15 Installation Under Wall Cabinet with Cabling 16 Wall Mounted Horizontal Vent 20 Cleaning and Maintenance 22 Technical Sp...

Page 4: ...4 Dimensions and Specifications Model Number Voltage Frequency Power Weight FH3011 120 V 60 Hz 233 W 35 lb 15 90 kg Tools Required 30 12 11 4 24 4...

Page 5: ...5 Model Number Voltage Frequency Power Weight FH3611 120 V 60 Hz 353 W 41 8 lb 19 kg Tools Required 36 12 11 4 4 24...

Page 6: ...6 Model Number Voltage Frequency Power Weight FH3018 120 V 60 Hz 353 W 43 6 lb 19 80 kg Tools Required 12 4 4 24 18 30...

Page 7: ...7 Model Number Voltage Frequency Power Weight FH3618 120 V 60 Hz 353 W 52 8 lb 24 kg Tools Required 36 12 4 4 24 18...

Page 8: ...8 Model Number Voltage Frequency Power Weight FH3624 120 V 60 Hz 706 W 68 lb 30 95 kg Tools Required Dual blower 36 4 4 24 24 12...

Page 9: ...Model Number Voltage Frequency Power Weight FH4818 120 V 60 Hz 706 W Dual blower 12 4 4 24 18 48 Tools Required 9...

Page 10: ...Model Number Voltage Frequency Power Weight FH4824 120 V 60 Hz 706 W Dual blower 12 24 24 4 4 48 Tools Required 10...

Page 11: ...issing or damaged contact the manufacturer Remove the bag of component accessories from inside the body of the hood Contents of bag according to model No 2 3 5 x 9 5 mm No 4 4 5 x 40 mm No 4 Dowel 8 N...

Page 12: ...ve equipment during installation Before installing the product remove the indicated accessories from the body of the hood as shown in the figures These parts must be removed even if they are not used...

Page 13: ...ood installation height requirements indicated in the cooktop range instructions take precedence over the requirements outlined in this manual If missing from the cooktop manual refer to the measures...

Page 14: ...14 Installation Horizontal Vent Option PRE CUT FH3011 FH3011 FH3611 FH3018 FH3618 Positioning of motor for horizontal vent...

Page 15: ...15 FH3611 FH3018 FH3618...

Page 16: ...16 Closing...

Page 17: ...ent Option PRE CUT FH3011 FH3611 FH3018 FH3618 25 32 147 5 25 32 155 6 7 64 FH3624 FH4818 FH4824 Only with reinforcing Wooden blocks 151 6 15 16 127 5 35 1 3 8 35 1 3 8 265 10 7 16 REAR FRONT Power Ca...

Page 18: ...Wall Mounted Horizontal Vent FH3011 FH3624 FH4818 FH4824 16 No 4 SCREWS M4x10mm 18...

Page 19: ...3011 FH3611 FH3018 FH3618 FH3624 FH4818 FH4824 FH3624 FH4818 FH4824 FH3011 FH3611 FH3018 FH3618 Model Number A Dimension Value B Dimension Value FH3011 51mm 2 176mm 6 59 64 FH3611 51mm 2 176mm 6 59 64...

Page 20: ...20 Installation Under Wall Cabinet FH4818 FH4824 Wooden Blocks i...

Page 21: ...21 Drywall Reinforcement Wall Installation FH3624 FH4818 FH4824...

Page 22: ...heck that all electrical parts lights exhaust device are off when the appliance is not being used Read the entire instruction booklet before performing any operations on the range hood The range hood...

Page 23: ...l ductwork WARNING To reduce the risk of a range top grease fire a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly...

Page 24: ...phase conductor the wire must not come into contact with hot parts over 70 C An appropriate plug for the power cable load is used and connected to a suitable electric socket For appliances supplied wi...

Page 25: ...ic grease filter Baffle Filters These capture the grease particles in the air They can be washed and must be cleaned every month with hot water and detergent The filters can be washed in the dishwashe...

Page 26: ...verage will include scratches stains surface imperfections on stainless steel paint and porcelain with the exclusion of slight differences in color due to materials and painting enameling technologies...

Page 27: ...onsumer 22 This warranty only covers service performed at the location of product installation and will not cover costs associated with repairing off site unless expressly authorized by Forza nor does...

Page 28: ...bilities of the buyer When writing or calling about a service problem please include the following information Your name address and telephone number Appliance model and serial number Name of your dea...

Page 29: ...nd will not cover costs associated with repairing off site unless expressly authorized by Forza nor does it cover the travel costs associated with providing service to remote locations 23 Replacement...

Page 30: ...30...

Page 31: ...31...

Page 32: ...Forza is a brand of Glem Gas S P A Via Modenese 4266 41018 San Cesario S P Modena Italy Web www forzacucina com Email service forzacucina com 3LIOU13GG 3 05 10 2020...

Reviews: