ForzaTracker
is a new generation of UPS monitoring software, which provides user-friendly interface to monitor
and control your UPS. This unique software provides safe auto-shutdown for multi-computer systems during
power failures. With this software, users can monitor and control any UPS on the same LAN no matter how far they
might be from the UPS.
Based on your operating system, select and download the correct version of the ForzaTracker from our website:
http://www.forzaups.com/us/driver-downloads.
The following steps are based on a Windows setup.
Open the software and follow the on-screen instructions to install it.
When you finished downloading all required files, enter the serial N° (installation password):
5242-87f6-64re-di8d-986u
to install the software (include the hyphens).
In order to access as Administrator, input the password:
111296
.
When your computer restarts, the management software will appear as a light blue round icon located in the
system tray, near the clock.
5. ForzaTracker monitoring software
6. Troubleshooting
4.3.1 Audible alarm
Installation procedure:
Condition
Alarm
Battery mode
Low battery
Overload
Fault
Sounds every 4 seconds
Sounds every second
Sounds twice every second
Continuous sound
Problem
Solution
Possible cause
LED fails to turn on
The UPS remains
in battery mode
Plug the power cord into the wall outlet or
press
ON/Mute
button to cold start the UPS
Allow the battery to recharge for at least 6 hours
Replace the battery.
Replug the power cord into the wall outlet
Allow the battery to recharge for at least 6 hours
The UPS is not on
Power cord is loose
Battery voltage is too low
Remove the least critical loads. Verify that the
load matches the UPS capability specified in
the specs before reconnecting the equipment
Overload
Replace the battery when it is weak or its
performance degraded
Defective battery
The UPS emits a
sustained alarm tone
Backup time shorter
than expected
Contact your dealer
Please check the fault code
for LED indicator description
Battery voltage is too low
Battery fault
1.
2.
3.
4.
5.
6.
Note:
For Mac and Linux users, please refer to the ForzaTracker user guide found in our website.
If the UPS fails to operate normally, please refer to the following table to solve most common installation and
operation problems.
If any other abnormal situation not listed above should occur, please call our service department for
further assistance.