Status LED Indications* 

 

Number of Blinks 

Meaning 

Fast Blinks, Normal Operation 

Wakeup Notification Sent (after quick switch press while in Network) 

Water Alarm 

Temperature Alarm (either high or low setpoint triggered) 

An active alarm has been cleared (when a water alarm or a temperature alarm is no longer active) 

Low Battery (repeated every approx. 40 seconds) 

Slow Blinks, After Battery Replacement or Inclusion / Exclusion 

In-Network (also, after button held while in-Network) 

Out of Network (also given if inclusion was not completed) 

*If the LED remains continually on after inserting a battery, please remove the battery and contact FortrezZ, LLC customer service. 

 

Choosing a mounting location 

The  WWA-02AA  is  suitable  for  use  in  dry,  interior  locations  only.      Avoid  placing  the  unit  close  to  a  metal  frame,  or  other  metal 
enclosures that may affect RF range.  Place the unit so that any leaks that may occur will not drip directly on the unit. 
Recommended WWA-02AA  uses:  Under  sink,  Next  to  Sump  pumps, Water  Heaters,  Laundry  Room,  Bathroom  Floor,  Storage  Area, 
Garage, Utility Sink, Vacation/Recreation homes, Boats, etc.

 

 

During an alarm 

If  water  is  detected  at  the  monitoring  location  or  an  over/under-temperature  conditions  is  detected,  the  unit  will  send  an  alert 
message(s)  to  the  Z-Wave

TM 

network  (if  included  in  the  network).    The  type  of  alert  message  depends  on  how  the  WWA-02AA  is 

configured.  If associations are configured, Basic Set messages will be sent as described above under 

Associations

.  If Water or Heat 

Alarms  have  been  configured  (via  Alarm  Command  Class  V2  Set  commands),  then  the  WWA-02AA  will  send  alert  messages  to  the 
Node ID that configured the alarm.  Association alert messages and Alarm alert messages may both be configured and sent.  Drying 
the sensor contacts will clear the Water Alarm.  If an over/under temperature Alarm occurred and the temperature alarm conditions are 
no longer present, an ‘alarm clear’ message is also sent to the Z-Wave

TM

 network (if included in the network).   

 
Also, depending on your Z-Wave

TM

 controller, it is possible to receive a remote alert.   For example, with some gateway controllers, you 

can receive an email or cell phone text message when an alarm is activated.  Depending on your specific controller’s capabilities you 
will be able to remotely check the status of any WWA-02AA in your network. 

 

Testing the WWA-02AA 

Moisten a paper towel and place over both of the small metal pads on the water sensor until you observe two quick LED blinks. The 
water alarm indication may take up to 4 or 5 seconds.  If the LED fails to blink, your battery may be old or dead or incorrectly installed, 
the sensor may not be moist enough, or the water sensor may be damaged.   If you see the LED blink, remove the moistened pape r 
towel and clean the small metal pads of any water residue and the LED should blink four times.  You can then add the WWA-02AA to 
your  Z-Wave

TM

  network  using  your  controller.    Examples  of  Z-Wave

TM

  controllers  can  be  found  on  the  FortrezZ  website 

(

www.fortrezz.com

). 

 

Battery / Low Battery 

The WWA-02AA will send an alert on the Z-Wave

TM

 network at regular intervals when it detects a low battery condition.  In addition, it 

will periodically blink the LED.  Your controller may be able to be configured to monito

r the unit’s wake up notifications.  If these stop, 

then this might also be an indication that the battery has died or that transmissions from the WWA-02AA are no longer being received. 
After  a  water  leak,  please  ensure  that  there  is  no  moisture  in  the  unit  and  around  the  battery.    Do  not  install  batteries  that  appear 
damaged  or  unsealed.    When  replacing  batteries,  the  water  seal  may  be  broken  around  the  screws.    After  screwing  the  parts  back 
together, the use of some sealant, such as silicone caulk, around the screws is recommended. 
 

Configuring the WWA-02AA 

The  high  and  low  temperature  setpoints  in  the WWA-02AA  can  be  configured.    The  low  temperature  setpoint  must  always  be  set  at 
least two degrees below the high temperature setpoint.  The low temperature  setpoint cannot be set less than 

–10 degrees C and the 

high  temperature  setpoint  cannot  be  set  greater  than  70  degrees  C.    The  temperature  setpoints  can  be  configured  via  a  ‘smart’ 
controller after inclusion; details are provided in the technical appendix. 

 
Temperature Reports 

If your controller sends the wakeup interval set command, the controller will also become the Wakeup Master node.  The WWA-02AA 
will automatically send temperature reports to this Wakeup Master node within a half hour of a 1 degree C change in temperature. 
 

Summary of Contents for WWA-02AA

Page 1: ...ode at the controller 2 Briefly press the switch once and the controller will indicate the unit has been included in the network Also the LED will blink when the inclusion completes Inclusion and exclusion are always done at normal transmit power mode Exclusion from removing from a network 1 Set up the exclusion mode at the controller 2 Press and hold the switch for approx 2 seconds until the cont...

Page 2: ...ateway controllers you can receive an email or cell phone text message when an alarm is activated Depending on your specific controller s capabilities you will be able to remotely check the status of any WWA 02AA in your network Testing the WWA 02AA Moisten a paper towel and place over both of the small metal pads on the water sensor until you observe two quick LED blinks The water alarm indicatio...

Page 3: ...circuitry that is not directly associated with the radio transmitter the device shall also have to comply with ICES 003 Class A or B as appropriate except for ICEC 003 labeling requirements The test data obtained for the ICES 003 tests shall be kept by the manufacturer or importer whose name appears on the equipment label and made available to Industry Canada on request for as long as the model is...

Page 4: ... heat alarm state When temperature alarm is no longer active sends Basic Set with Value 0x00 to association nodes as above and or sends Alarm Command Class Heat Report Unknown Event 0xFE with Alarm Level 0x00 BATTERY STATUS Battery level percentage estimated based on number of Wakeup1 s see below since battery insertion In addition battery voltage readings can trip the low battery state Low batter...

Reviews: