TECHNICAL APPENDIX 

 

MANUFACTURER ID

 

0x0084 

 

 

 

 

PRODUCT ID

 

 

varies 

 

 

 

 

PRODUCT TYPE ID

 

0x0063 (US)     0x0061 (EU) 

DEVICE CLASS

  

 

Generic Type Sensor MultiLevel, Specific Type Routing Sensor Multilevel 

 

COMMAND CLASSES SUPPORTED

 (in addition to COMMAND_CLASS_BASIC) 

COMMAND_CLASS_ALARM_V2 
COMMAND_CLASS_WAKE_UP_V2 
COMMAND_CLASS_CONFIGURATION 
COMMAND_CLASS_ASSOCIATION 

COMMAND_CLASS_BATTERY 
COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_SENSOR_MULTILEVEL 
COMMAND_CLASS_VERSION 

 

WATER ALARM

 

  Sampling every 4 seconds 

  Z-Wave

TM

  transmissions  (eve

ry approx. 30 minutes while alarm is active): ‘Basic Set’ with Value = 0xFF sent to associated nodes in Group 1 

and/or Group 2 and/or an Alarm Command Class V2 Water Leak Report (Event = Water Leak Detected, Unknown Location, 0x02AA with Alarm 
Level = 0xFF.  What is sent depends on whether associations are configured and/or Water Leak Alarm is enabled with a non-zero destination 
Node ID (see Alarm Factory Default State under OTHER below). 

  Visual indication of water alarm via LED 

  Alarm Command Class V2 Get (Sensor Type = 0x05, Water Leak) can be used to request water alarm state 

 

When water alarm is no longer active, sends ‘Basic Set’ with Value = 0x00 to association nodes as above and/or Alarm Command  Class Water 
Leak Report (Unknown Event, 0xFE) with Alarm Level = 0x00 

 

UNDER-TEMPERATURE / OVER-TEMPERATURE ALARM 

  Sampling every 4 seconds with averaging algorithm 

  Sensor has an accuracy of approx. +/-2 degC.  Default alarm trigger points set at approx. 4 degC and 70 degC 

  Z-Wave

TM

  transmissions  (every  approx.  30 

minutes while alarm is active): ‘Basic Set’ with Value = 0xFF sent to associated nodes in Group 1 

and/or  Group  3  and/or  Alarm  Command  Class  V2  Heat  Report  with  Alarm  Level  =  0xFF  and  Event  =  [Overheat  Detected,  unknown  location, 
0x02AA or Underheat Detected, unknown location, 0x06].  What is sent depends on whether associations are configured and/or Heat Alarm is 
enabled with a non-zero destination Node ID (see Alarm Factory Default State under OTHER below). 

  Visual Indication of temperature alarm via LED 

  Alarm Command Class V2 Get (Sensor Type = 0x04, Heat) can be used to request heat alarm state 

 

When temperature alarm is no longer active, sends ‘Basic Set’ with Value = 0x00 to association nodes as above and/or sends Alarm Command 
Class Heat Report (Unknown Event, 0xFE) with Alarm Level = 0x00 

 

BATTERY STATUS 

 

Battery level percentage estimated based on number of Wakeup1’s (see below) since battery insertion 

  In addition, battery voltage readings can trip the low battery state 

  Low battery report (Battery Command Class) every approx. 30 minutes after low battery becomes active 

  Visual indication of low battery every approx. 40 seconds 

 

WAKEUPS 

  Wakeup1: Power saving design wakes up every 4 seconds to test water and freeze sensor 

  Wakeup2: Once every approx. 4 hours (default) unit wakes up to send a notification either to a wakeup node or broadcast. The unit stays awake 

for approx. 5 seconds or while communicating with a controller.  Sensors are not checked during this time. 

  The Wakeup node is the node configured to receive the Wakeup Notification command.  This is set in the WWA-02AA by the Wakeup Interval 

Set command and is typically the Controller node.  Only one value for the wakeup interval, the default interval of 0x003840 (4 hours), can be set. 

 

MULTILEVEL SENSOR 

  Multilevel Sensor Report sent with current Temperature (Degrees C) in response to Multilevel Sensor Get command 

  Unsolicited Multilevel Sensor Report sent to Wakeup Node within 30 minutes of a 1 degree temperature change (if Wakeup node is set); filtering 

is applied to avoid ‘oscillating’ report transmissions and conserve battery life; transmission is independent of a Wakeup Notification 

 

CONFIGURATION 

  Parameter 1 sets Low Temperature Trigger Point (degrees Centigrade, 1 signed byte, Default = 4) 

  Parameter 2 sets High Temperature Trigger Point (degrees Centigrade, 1 signed byte, Default = 70) 

 

KEEP-ALIVE 

  Switch activated causes 30 sec RF receiver-on time intended for Controller configuration after network inclusion 

  Sensors not checked during Keep-Alive time 

 

OTHER 

  Alarm Factory default state = Enabled; unsolicited alarm reports (underheat, overheat, and water leak) will be sent to Node 0x01 (after inclusion).  

This Node ID can be changed via the Alarm Set Command (Alarm Command Class V2) 

  All Network Inclusions / Exclusions are at normal power levels 

  Up to 5 nodes allowed in each association group 

  Basic Report sent in response to a Basic Get with value equal to Multilevel Sensor Type (Temperature, 0x01) 

  Built with Z-Wave

TM

 SDK 4.51 

 
 

Summary of Contents for WWA-02AA

Page 1: ...ode at the controller 2 Briefly press the switch once and the controller will indicate the unit has been included in the network Also the LED will blink when the inclusion completes Inclusion and exclusion are always done at normal transmit power mode Exclusion from removing from a network 1 Set up the exclusion mode at the controller 2 Press and hold the switch for approx 2 seconds until the cont...

Page 2: ...ateway controllers you can receive an email or cell phone text message when an alarm is activated Depending on your specific controller s capabilities you will be able to remotely check the status of any WWA 02AA in your network Testing the WWA 02AA Moisten a paper towel and place over both of the small metal pads on the water sensor until you observe two quick LED blinks The water alarm indicatio...

Page 3: ...circuitry that is not directly associated with the radio transmitter the device shall also have to comply with ICES 003 Class A or B as appropriate except for ICEC 003 labeling requirements The test data obtained for the ICES 003 tests shall be kept by the manufacturer or importer whose name appears on the equipment label and made available to Industry Canada on request for as long as the model is...

Page 4: ... heat alarm state When temperature alarm is no longer active sends Basic Set with Value 0x00 to association nodes as above and or sends Alarm Command Class Heat Report Unknown Event 0xFE with Alarm Level 0x00 BATTERY STATUS Battery level percentage estimated based on number of Wakeup1 s see below since battery insertion In addition battery voltage readings can trip the low battery state Low batter...

Reviews: