CAUTION! Before you turn on the two parallel connected Fortress Power Batteries, make
sure both batteries have the same State Of Charge (SOC) and the voltage difference between
two battery pack shall not over 0.2 voltage to avoid the current flow from the higher voltage
battery into the lower voltage battery. The large current could potentially damage one or both
batteries.
6 RETROFITTING
Retrofit Fortress Lithium batteries to an existing system is not recommended. Like all other batteries,
Fortress Lithium Battery’s open voltage will diminish during the operation. Parallel batteries with
different open voltage may cause reverse currents, which could damage the batteries.
7 OPERATING
7.1 Operating environment
Model
LFP-5
LFP-10
Charging Temperature [F]
32~113
32~113
Discharging Temperature [F]
-4~140
-4~140
7.2 Charging
Never attempt to charge a battery without first reviewing and understanding the instructions for the
charger being used.
Only use a Fortress Power Approved Lithium Ferro Phosphate (LFP) charger if
ancillary charging is required before installation, testing or troubleshooting. Failure to use a Fortress
Power approved LFP charger will damage the battery and void the warranty
CAUTION! Do not attempt to charge the battery below 32 F (0 degrees C). Attempts to
charge at subfreezing temperatures can adversely affect State of Health (SOC) and cycle life
and will void the warranty; never charge battery if it is frozen; never charge a visibly damaged
battery.
Please follow the following steps to use the charger to charge the battery:
1)
Connect the charger leads to the battery.
2)
Make sure that the charger lead, both at the charger and the battery side, connections are tight.
3)
Turn the charger on
CAUTION! Recommended charging current is LFP5: 30A, Max. 50A LFP10: 50A Max