background image

A

MOUNT HEATER HERE

USING THE (4) 

THREADED HOLES

REMOVE TURBINE BOX AS SHOWN

TO MAKE IT EASIER TO INSTALL HEATER

PLUG HEATER IN HERE

ROUTE HEATER CABLE 

UP THRU HERE

NOTE - HEATER HAS AN INLINE

THERMOSTAT THAT WILL ONLY

TURN THE HEATER ON WHEN IT

GETS BELOW 50°f AND WILL 

THEN TURN THE HEATER OFF 

ONCE THE TEMPERATURE GETS

ABOVE 70°f

5000RT CUSTOMER HEATER INSTALLATION

P-30

Summary of Contents for 5000RT Series

Page 1: ...5000RT AUTO AND MANUAL TELLER REMOTE TELLER SYSTEM INSTALLATION MANUAL SEPT 2020 ...

Page 2: ...CATIONS 14 MANUAL TELLER OPERATION DESCRIPTIONS 15 MANUAL TELLER WALL MOUNT INSTALLATION 16 MANUAL TELLER SYSTEM SPECIFICATIONS 17 MANUAL TELLER COUNTER CLEAR VIEW INSTALLATION 18 FIELD WIRING CONNECTION LOCATIONS 19 5000RT CONTROL COMPONENTS 20 FIELD WIRING 21 5000RT A AND 5000DS TIMER ADJUSTMENTS 22 5000RT M AND 6000RT TIMER ADJUSTMENTS 24 5000RT A START UP PROCEDURE 26 5000RT M START UP PROCEDU...

Page 3: ...CATED IN THE UPPER PORTION OF THE TELLER UNIT THE CUSTOMER UNIT REQUIRES A 120 VOLT 30 AMP DEDICATED CIRCUIT THE TELLER UNIT REQUIRES A 120 VOLT 15 AMP CIRCUIT 5000RT M THIS PRODUCT CODE INCLUDES A 5000RT CUSTOMER STATION WITH A STANDARD BLOWER PACKAGE 2 BLOWERS AND MANUAL TELLER STATION IT IS A PUSH PULL STYLE SYSTEM THAT IS ONLY AVAILABLE IN A 4 1 2 CONFIGURATION THE CONTROLS ARE LOCATED IN THE ...

Page 4: ...VOLT 20 AMP CIRCUIT REQUIRES A L5 20R RECEPTACLE STANDARD BLOWER 120 VOLT 30 AMP CIRCUIT REQUIRES A L5 30R RECEPTACLE QUAD BLOWER CONTROL CABLE SPECIFICATIONS 8 CONDUCTOR 20 GA CABLE REQUIRED FOR LENGTHS OVER 200FT AN 18 GA IS REQUIRED AUDIO COMPONENT SPECIFICATIONS Speaker 8 ohm Microphone 2K impedance condenser type P 4 ...

Page 5: ... 8 17 7 8 4 4 3 4 10 11 16 ANCHOR HOLES 5 8 DIA 4 PLCS CONDUITS ARE TO BE LOCATED WITHIN THIS AREA CARRIER TUBE CENTER TRAFFIC USING THESE ANCHORING LOCATIONS WITH PLACE THE UNIT 5 FROM THE FRONT OF ISLAND 5000RT CUSTOMER ISLAND DETAIL P 5 ...

Page 6: ...HE AUDIO AUTHORITY SYSTEM DOES NOT ALLOW THE CHIME TO CONSTANTLY RING IF SOMEONE HOLDS THE BUTTON IN THERE NEEDS TO BE A 5 SECOND DELAY BETWEEN BUTTON PRESSES FOR THE CHIME TO RING A SECOND TIME 5000RT CUSTOMER OPERATIONAL DESCRIPTION THERE IS A SAFETY CIRCUIT THAT WILL CAUSE THE DOOR TO REOPEN IF THERE IS AN OBSTRUCTION IN THE WAY OF THE DOOR WHEN IT CLOSES ONCE THE OBSTRUCTION IS CLEARED YOU MUS...

Page 7: ...S THESE ARE LOCATED ON THE INSIDE OF THE CABINET DIRECTLY BEHIND THE UPPER LEFT AND RIGHT HAND CORNERS OF THE FRONT PANEL ONCE THESE ARE LOOSENED PULL THE TOP OF THE FRONT PANEL TOWARD YOU AND LIFT OFF OF BASE BE CAREFUL THERE IS A WIRING HARNESS ATTACHED TO THE BACK SIDE OF THE SWITCHES WING BOLTS BEHIND FRAME 5000RT CUSTOMER SERVICE PANEL AND FRONT REMOVAL P 7 ...

Page 8: ...AND TELLER TUBING CONNECTIONS TELLER TUBE CONNECTION THE TELLER TUBE CONNECTION FOR THE AUTOMATIC AND THE MANUAL TELLER UNITS ARE THE SAME IF YOU ARE USING STEEL TUBE THEN YOU WILL BE USING THE CLAMP SLEEVE IF IT IS PVC PIPE THEN YOU WILL BE USING THE PLASTIC ADAPTER BOTH ARE SUPPLIED WITH THE SYSTEM NOTE APPLY A BEAD OF SILICONE TO THE TOP AND BOTTOM OF THE TUBING ADAPTER WHEN USED P 8 ...

Page 9: ...LEX HOSE HOSE CLAMPS CHECK VALVE PORT CHECK VALVE ASSEMBLY FS55 0150 5000RT CHECK VALVE ASSEMBLY WHEN INSTALLING CHECK VALE ALWAYS MOUNT SO THAT THE VALVE FLAP IS HANGING DOWN OR IS ON TOP SEE ILLUSTRATIONS BELOW OK OK NOT OK NOT OK X X P 9 ...

Page 10: ...IFICATIONS 5000RT AUTO TELLER ELECTRICAL SPECIFICATIONS 120 VOLT 15 AMP CIRCUIT REQUIRED TELLER UNIT CAN BE ON SAME CIRCUIT AS CUSTOMER UNIT CONTROL CABLE SPECIFICATIONS 8 CONDUCTOR 20 GA CABLE REQUIRED FOR LENGTHS OVER 200FT AN 18 GA IS REQUIRED P 10 ...

Page 11: ...SED THE CUSTOMER DOOR WILL CLOSE AFTER TWO SECONDS THE PRESSURE TURBINE RELAY WILL BE ENERGIZED SET RUNTIME WILL DETERMINED HOW LONG THE PRESSURE RELAY IS ACTIVE ONCE THE TURBINE RELAY IS DEACTIVATED THE TELLER DOOR WILL OPEN NOTE IF THE CUSTOMER DOOR SAFETY IS ACTIVATED AT ANYTIME DURING THE CUSTOMER DOOR CLOSING THE CUSTOMER DOOR WILL RE OPEN AND THE SEQUENCE WILL HAVE TO BE RE STARTED ONCE THE ...

Page 12: ...LL CAN SUPPORT TELLER UNIT 3 8 THREADED ROD 3 8 JAM NUT 4 PLCS 3 8 JAM NUT 8 PLCS 5000RT AUTO TELLER WALL MOUNT INSTALLATION SPECIFICATIONS WALL MOUNT BRACKET SHOULD ALWAYS BE ABOVE THE CEILING SO THE TELLER UNIT CAN EITHER BE BOLTED DIRECTLY TO THE BRACKET OR IT CAN BE SUSPENDED WITH THREADED ROD AS SHOWN P 12 ...

Page 13: ...SYSTEM SPECIFICATIONS 5000RT WITH AUTO TELLER 120 REFERENCE 96 TO CEILING P 13 ...

Page 14: ...1 5 8 ADJUSTMENT REFERENCE WALL REFERENCE COUNTER DIMENSIONAL SPECIFICATIONS 5000RT MANUAL TELLER ELECTRICAL SPECIFICATIONS NONE REQUIRED CONTROL CABLE SPECIFICATIONS 8 CONDUCTOR 20 GA CABLE REQUIRED FOR LENGTHS OVER 200FT AN 18 GA IS REQUIRED P 14 ...

Page 15: ...OMER DOOR IS OPEN WHEN PRESSED THE CUSTOMER DOOR WILL CLOSE AFTER TWO SECONDS THE PRESSURE TURBINE RELAY WILL BE ENERGIZED SET RUNTIME WILL DETERMINED HOW LONG THE PRESSURE RELAY IS ACTIVE ONCE THE TURBINE RELAY IS DEACTIVATED THE TELLER DOOR WILL OPEN NOTE IF THE CUSTOMER DOOR SAFETY IS ACTIVATED AT ANYTIME DURING THE CUSTOMER DOOR CLOSING THE CUSTOMER DOOR WILL RE OPEN AND THE SEQUENCE WILL HAVE...

Page 16: ...NGED TUBE ADAPTER FLANGE GASKET 3 VENT TUBE EXPANDED END 3 8 ANCHORS SHOULD BE USED TO SECURE BRACKET TO WALL MAKE SURE WALL CAN SUPPORT WEIGHT OF FULLY ASSEMBLED TELLER UNIT AND TUBE FLANGED TUBE CONNECTION ALLOWS TELLER UNIT TO BE ROTATED LEFT AND RIGHT 16 INCHES IS THE RECOMMENDED DISTANCE THAT THE BOTTOM OF THE TELLER UNIT SHOULD BE ABOVE COUNTER 5000RT MANUAL TELLER WALL MOUNT BRKT AND TELLER...

Page 17: ...SYSTEM SPECIFICATIONS 5000RT WITH MANUAL TELLER P 17 5000RT ...

Page 18: ...TH TWO WOOD SCREWS RE INSTALL LANDING PAD WHEN ANCHORING IS COMPLETE USE SILICONE SEALANT ON BOTH ENDS OF COUPLING USE SILICONE SEALANT ON BOTH ENDS OF COUPLING P 18 CLEAR VIEW CLEAR VIEW ADAPTER COUNTER TOP INSTALLATION 5000RT MANUAL TELLER COUNTER TOP ITEM NO PART NUMBER DESCRIPTION QTY 7 FS13 0588 CLEARVIEW ADAPTER TUBE 1 30 TU 010 STEEL TO CLEARVIEW ADAPTER 1 31 TU 001 7FT CLEARVIEW 1 32 TU 02...

Page 19: ...NNECTOR REMOVE FRONT PANEL OF TELLER UNIT 4 SCREWS BE CAREFUL WHILE REMOVING FRONT PANEL THERE IS A CABLE ATTACHED THAT GOES TO THE DOOR POSITION SENSOR DOOR POSITION SENSOR FIELD WIRING CONNECTOR 5000RT AUTO TELLER CONTROL COMPONENT LOCATIONS 5000RT MANUAL TELLER CONTROL COMPONENT LOCATIONS P 19 ...

Page 20: ...MTR FUSE HEATER FUSE DOOR MOTOR AND AUDIO VIDEO FUSE TURBINE CONNECTOR FIELD WIRING CONNECTOR DOOR MOTOR CONNECTOR AUDIO MUTE TURBINE RELAYS DOOR MTR RELAY 5000RT CUSTOMER CONTROL COMPONENT LOCATIONS NOTE STANDARD CONTROL BOX SHOWN SEE DETAIL ELECTRICAL BOX INFORMATION FOR OTHER VARIATIONS P 20 ...

Page 21: ...VE A CONNECTOR STYLE A ON CUSTOMER END AND A CONNECTOR STYLE B ON THE TELLER END THESE CONNECTORS COME WITH SHORT COLOR CODED WIRES CONNECT THESE COLOR TO COLOR WITH YOUR CONTROL CABLE NOTE THE YELLOW AND ORANGE WILL NOTE BE USED ON A 5000RT CUSTOMER UNIT WHEN CONNECTED TO A AUTOMATIC TELLER NOTE ALL FORTIS MACHINES WILL ALWAYS HAVE THE COLOR CODE ON THE TELLER UNIT MATCH THE COLOR CODE ON THE CUS...

Page 22: ...CALLY STOP AFTER 15 TRANSACTIONS OR YOU CAN STOP BY PRESSING THE DOWN ARROW KEY FOR ONE SECOND ONCE IT HAS STOPPED IT AUTOMATICALLY RESETS AND IS READY TO RUN AGAIN TO CHANGE RUNTIME PRESS THE OK BUTTON ONE TIME THIS WILL TAKE YOU TO THE SCREEN SHOWN ABOVE PRESS THE DOWN ARROW BUTTON ONE TIME SO THAT PARAMETERS IS FLASHING PRESS THE OK BUTTON THIS WILL TAKE YOU TO THE PARAMETER LIST USING THE UP A...

Page 23: ...WILL RE OPEN AND THE TIMER WILL RESET TO 0 AND START COUNTING AGAIN ONCE THE TIMER REACHES 180 SECONDS THE CUSTOMER DOOR WILL CLOSE WITH THE CARRIER IN THE CUSTOMER STATION PRESSING THE CUSTOMER SEND SWITCH WILL CAUSE THE DOOR TO OPEN AND THE TIMER TO RESET TO 0 THIS FEATURE CAN BE TURNED ON OR OFF IT IS FACTORY SET TO OFF YOU CAN TURN THIS FEATURE ON BY CHANGING C13 SEE BELOW PARAMETERS DO NOT CH...

Page 24: ...ALLY STOP AFTER 15 TRANSACTIONS OR YOU CAN STOP BY PRESSING THE DOWN ARROW KEY FOR ONE SECOND ONCE IT HAS STOPPED IT AUTOMATICALLY RESETS AND IS READY TO RUN AGAIN TO CHANGE RUNTIME PRESS THE OK BUTTON ONE TIME THIS WILL TAKE YOU TO THE SCREEN SHOWN ABOVE PRESS THE DOWN ARROW BUTTON ONE TIME SO THAT PARAMETERS IS FLASHING PRESS THE OK BUTTON THIS WILL TAKE YOU TO THE PARAMETER LIST USING THE UP AN...

Page 25: ...WILL RE OPEN AND THE TIMER WILL RESET TO 0 AND START COUNTING AGAIN ONCE THE TIMER REACHES 180 SECONDS THE CUSTOMER DOOR WILL CLOSE WITH THE CARRIER IN THE CUSTOMER STATION PRESSING THE CUSTOMER SEND SWITCH WILL CAUSE THE DOOR TO OPEN AND THE TIMER TO RESET TO 0 THIS FEATURE CAN BE TURNED ON OR OFF IT IS FACTORY SET TO OFF YOU CAN TURN THIS FEATURE ON BY CHANGING C13 SEE BELOW PARAMETERS DO NOT CH...

Page 26: ...ELLER DOOR TRAVEL IF DOOR IS CLEAR AND STILL RE OPENS ADJUST SAFETY SWITCH SO THAT IT IS LESS SENSITIVE 7 PRESS CUSTOMER SEND SWITCH 8 CUSTOMER DOOR SHOULD CLOSE THE PRESSURE TURBINE SHOULD RUN FOR 6 SECONDS 9 ONCE THE TURBINE SHUTS OFF THE TELLER DOOR SHOULD OPEN IF AT ANY TIME THE CUSTOMER DOOR OPENS CHECK FOR AN OBSTRUCTION TO THE DOOR TRAVEL IF THE PATH OF THE DOOR IS CLEAR ADJUST SAFETY SWITC...

Page 27: ...PENED IF AT ANY TIME THE CUSTOMER DOOR OPENS CHECK FOR AN OBSTRUCTION TO THE DOOR TRAVEL IF THE PATH OF THE DOOR IS CLEAR ADJUST SAFETY SWITCH SO THAT IT IS LESS SENSITIVE SEE SAFETY SWITCH ADJUSTMENT PROCEDURE 6 ONCE YOU MAKE SURE THAT THE SYSTEM WILL SEND THE CARRIER BACK AND FORTH AND THE DOORS ARE WORKING CORRECTLY ADJUST THE TURBINE RUN TIMES SO THAT THE TURBINES RUN FOR A FULL 2 SECONDS AFTE...

Page 28: ...O DECREASE SPRING TENSION SAFETY SWITCH TENSION INDICATOR SHOULD BE ADJUSTED SO THAT THERE IS APPROX 1 2 BECAUSE THE 3 MOUNTING HOLES ARE SLOTTED IT IS VERY EASY TO REMOVE ASSEMBLY TO VIEW INDICATOR DOOR CLOSED SWITCH DOOR OPEN SWITCH SAFETY SWITCH SAFETY SWITCH SHOULD BE ADJUSTED SO THAT THE MOTOR HAS TO ROCK APPROX 1 8 BEFORE SWITCH IS ACTIVATED 5000RT CUSTOMER SAFETY SWITCH ADJUSTMENT PROCEDURE...

Page 29: ...THE SHOULD BOLT DOES NOT ENTER LARGE HOLE AT THE END OF SLOT THIS CAN CAUSE THE SAFETY SWITCH TO TRIP WHEN THE DOOR STARTS TO CLOSE ALWAYS ADJUST SO THAT THE ARM STOPS WITH THE SHOULDER BOLT APPROX 1 4 FOR LARGER CUT OUT DOOR OPEN SWITCH DOOR CLOSED SWITCH SAFETY SWITCH DOOR OPEN AND CLOSED LIMIT SWITCHES ARE ADJUSTED BY BENDING THE ARM OF THE SWITCH WHEN BENDING ARM BE CAREFUL NOT TO BREAK SWITCH...

Page 30: ...T EASIER TO INSTALL HEATER PLUG HEATER IN HERE ROUTE HEATER CABLE UP THRU HERE NOTE HEATER HAS AN INLINE THERMOSTAT THAT WILL ONLY TURN THE HEATER ON WHEN IT GETS BELOW 50 f AND WILL THEN TURN THE HEATER OFF ONCE THE TEMPERATURE GETS ABOVE 70 f 5000RT CUSTOMER HEATER INSTALLATION P 30 ...

Page 31: ... CONNECTIONS 5000RT CUSTOMER CAMERA INSTALLATION CAMERA CAN BE SLIDE IN PLACE FROM THE SIDE SERVICE DOOR AREA OR THRU THE MONITOR OPENING FOUR SCREWS ARE SUPPLIED TO FASTEN CAMERA IN PLACE CAMERA CONNECTS TO THE AV 1520 LANE STATION WITH A CAT 5 CABLE THAT PLUGS INTO THE VIDEO ADD ON PORT ON THE LANE STATION P 31 ...

Page 32: ...GASKET MAKE SURE THAT THE THREADED STAND OFFS ARE INSTALLED BEFORE MOUNTING MONITOR 5 PIN PLUG ON MONITOR CABLE GOES HERE THE OTHER END OF CABLE CONNECTS TO CAMERA SEE CAMERA INSTALLATION SHEET TOP OF MONITOR 5000RT CUSTOMER MONITOR INSTALLATION P 32 ...

Page 33: ... BEING SENT TO MONITOR CONNECTED TO VIDEO MODULE PORT CAT 5 FROM HUB OPTION HANDSET 5000RT CUSTOMER AUDIO CONNECTIONS 5000RT AUDIO WIRING WIRES ARE TY WRAPPED TOGETHER NEXT TO LANE STATION LOCATION 1 GRAY SHIELD CABLE MICROPHONE RED MIC BLACK MIC SHIELD COMMON 2 RED AND BLACK PAIR FROM SPEAKER RED SPEAKER BLACK SPEAKER 3 TWO RED AND BLACK TWISTED PAIRS BOTH REDS CALL BUTTON BOTH BLACKS COMMON 4 OR...