NEW FEATURE
WE HAVE ADDED A FEATURE THAT WILL AUTOMATICALLY CLOSE THE CUSTOMER
DOOR WHEN THE CARRIER IS OUTSIDE. EACH TIME THE CUSTOMER DOOR OPENS
A TIMER STARTS COUNTING. IF AT ANY POINT BEFORE THE TIMER REACHES IT'S
SET POINT (FACTORY SETTING IS 180 SECONDS) THE CUSTOMER SEND OR TELLER
RECALL ARE PRESSED THE TIMER WILL RESET TO "0" AND WILL NOT START COUNTING
UNTIL THE CARRIER IS SENT BACK TO THE CUSTOMER UNIT AND THE DOOR OPENS.
IF THE SAFETY SWITCH ACTIVATES AT ANYTIME DURING THE DOOR CLOSING
THE DOOR WILL RE-OPEN AND THE TIMER WILL RESET TO "0" AND START COUNTING
AGAIN. ONCE THE TIMER REACHES 180 SECONDS THE CUSTOMER DOOR WILL CLOSE
WITH THE CARRIER IN THE CUSTOMER STATION. PRESSING THE CUSTOMER SEND
SWITCH WILL CAUSE THE DOOR TO OPEN AND THE TIMER TO RESET TO "0".
THIS FEATURE CAN BE TURNED ON OR OFF. IT IS FACTORY SET TO OFF. YOU CAN
TURN THIS FEATURE ON BY CHANGING
C13
(SEE BELOW)
PARAMETERS
DO NOT CHANGE ANY OTHER PARAMETERS OTHER THAN THESE
T-3 OUTBOUND RUN TIME
T-5 INBOUND RUNTIME
T-16 ANTI-CONDENSATE FEATURE (I1= PRESS MTR ON TIME IN SECONDS
I2 = OFF TIME IN MINUTES BETWEEN PULSES OF AIR)
C13 - OFF = 10 ON = 1 (WHEN CHANGING YOU WILL NOTICE 0000000010= OFF)
BUT WHEN YOU FIRST GO INTO C13 IT WILL D10)
P-23