FortiGate-3810A FortiOS 3.0 MR6 Install Guide
12
01-30006-0456-20080131
Cautions and warnings
Installing
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The equipment compliance with FCC radiation exposure limit set forth for
uncontrolled Environment.
Cautions and warnings
Review the following cautions before installing your FortiGate unit.
Grounding
• Ensure the FortiGate unit is connected and properly grounded to a lightning
and surge protector. WAN or LAN connections that enter the premises from
outside the building should be connected to an Ethernet CAT5 (10/100 Mb/s)
surge protector.
• Shielded Twisted Pair (STP) Ethernet cables should be used whenever
possible rather than Unshielded Twisted Pair (UTP).
• Do not connect or disconnect cables during lightning activity to avoid damage
to the FortiGate unit or personal injury.
Rack mount instructions
Elevated Operating Ambient
- If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than
room ambient. Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
Reduced Air Flow
- Installation of the equipment in a rack should be such that
the amount of air flow required for safe operation of the equipment is not
compromised.
Mechanical Loading
- Mounting of the equipment in the rack should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading
- Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing
- Reliable earthing of rack-mounted equipment should be
maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
Mounting
If required to fit into a rack unit, remove the rubber feet from the bottom of the
FortiGate unit.
The FortiGate unit can be placed on any flat surface, or mounted in a standard 19-
inch rack unit.
Summary of Contents for FortiGate FortiGate-3810A
Page 1: ...www fortinet com FortiGate 3810A FortiOS 3 0 MR6 I N S T A L L G U I D E ...
Page 6: ...FortiGate 3810A FortiOS 3 0 MR6 Install Guide 6 01 30006 0456 20080131 Contents ...
Page 59: ...FortiGate 3810A FortiOS 3 0 MR6 Install Guide 59 01 30006 0456 20080131 Index ...
Page 60: ...FortiGate 3810A FortiOS 3 0 MR6 Install Guide 60 01 30006 0456 20080131 Index ...
Page 61: ...www fortinet com ...
Page 62: ...www fortinet com ...