![Fortinet FortiGate-7000E Series System Manual Download Page 56](http://html1.mh-extra.com/html/fortinet/fortigate-7000e-series/fortigate-7000e-series_system-manual_2321753056.webp)
FortiGate-7060E System Management Modules
Fortinet Technologies Inc.
Use the following command to power on the FIM in slot 2 (IPMI address 0x84):
fru activate 0x84
Use the following IPMI command to reset the module SMC to reboot the FPM in slot 3:
sudo ipmitool -I lanplus -H 10.160.19.30 -k gkey -U admin -P admin -t 0x86 mc reset warm
Use the following IPMI command to power off the FPM in slot 4:
sudo ipmitool -I lanplus -H 10.160.19.30 -k gkey -U admin -P admin -t 0x88 picmg deactivate 0
Use the following IPMI command to power on the FIM in slot 2 (IPMI address 0x84):
sudo ipmitool -I lanplus -H 10.160.19.30 -k gkey -U admin -P admin -t 0x84 picmg activate 0
Comlog
All FIM and FPM SMCs include a comlog system for writing and saving console log messages. When enabled, the
comlog saves log messages in a local comlog file. Log messages include all local host console messages including
BIOS boot up messages. In the comlog these messages include the following headers:
Header
Cause
\n--- COMLOG SYSTEM BOOT: YYYY/MM/DD hh:mm:ss ---\n
The module is starting up after being powered on
or reset.
\n--- COMLOG DISABLED: YYYY/MM/DD hh:mm:ss ---\n
Logging is disabled.
\n--- COMLOG ENABLED: YYYY/MM/DD hh:mm:ss ---\n
Logging is enabled
\n--- COMLOG TIME: YYYY/MM/DD hh:mm:ss ---\n
This message is written every hour when the
module is powered on and logging is enabled.
The following comlog-related CLI commands are available:
Description
SMC CLI Commands
IPMI commands
Display comlog information.
Available on the passive
module.
comlog getinfo
Status
Disabled
COM
Speed 9600
Storage Size
0x00400000
Log Start
0x00000000
Log End
0x00000C37
Log Size
3127 Bytes
Display a module's comlog.
Available on the passive
module.
comlog getinfo <slot>
comlog print <slot>
fortinetoem comlog getinfo
fortinetoem comlog print
Clear a module's comlog. Either
by resetting the a comlog start
location in flash (reset_loc) or
erasing all of the flash storage
comlog clear [reset_loc]
[chip_erase]
fortinetoem comlog clear
FortiGate-7060E 6.4.2 System Guide
56