The FortiGate unit can be placed on any flat surface, or mounted in any standard 19in
(48.3cm) rack unit with the provided rack-mount brackets and screws.
Caution:
Electrostatic discharge (ESD) can damage your Fortinet equipment.
Caution:
Do not place heavy objects on the unit.
To install the FortiGate unit into a rack:
Caution:
To avoid personal injury or damage to the unit, it is recommended that two or
more people install the unit into the rack.
1.
Ensure that the FortiGate unit is placed on a stable surface prior to rack-mount
installation.
2.
Attach the provided rack-mount brackets to the sides of the unit using the provided
screws.
a.
If you are installing the unit into a four-post rack, attach the rack-mount brackets
with the handles aligned with the front of the unit.
b.
If you are installing the unit into a two-post rack, attach the rack-mount brackets
with the handles aligned with the middle of the unit.
2. Installation
3.
Position the FortiGate unit in the rack. Ensure there is enough room around the unit to
allow for sufficient air flow.
4.
Line up the rack-mount bracket holes to the holes on the rack and ensure that the
FortiGate unit is level.
5.
Finger tighten four rack-mount screws to attach the unit to the rack.
6.
Verify that the spacing around the FortiGate unit conforms to requirements and that
the unit is level, then tighten the rack-mount screws with an applicable screwdriver.
7.
Using the provided power cables, plug the cables into the rear of the unit and then into
an electrical outlet.
Note
: If the unit has a redundant power supply, each power cable should be connected
to a different power source. In this way, if one power source fails, the other may still be
operational and the unit will not lose power.
To install the unit on a flat surface:
1.
Ensure that the surface onto which the FortiGate unit to be installed is clean, level,
and stable and that there is at least 1.5in (3.5cm) of clearance on all sides to allow for
adequate airflow.
2.
Attach the provided rubber feet to the bottom of the FortiGate unit.
3.
Place the unit in the designated location.
4.
Verify that the spacing around the FortiGate unit conforms to requirements and that
the unit is level.
5.
Using the provided power cables, plug the cables into the rear of the unit and then into
an electrical outlet.
Note
: If the unit has a redundant power supply, each power cable should be connected
to a different power source. In this way, if one power source fails, the other may still be
operational and the unit will not lose power.
Caution:
Do not place heavy objects on the unit.
1.5in
1.5in
Summary of Contents for FortiGate-600C
Page 1: ...FortiGate 600C QuickStart Guide ...
Page 13: ......