FortiGate-5001FA2-LENC Security System Guide
10
01-30000-76602-20080606
Installing SFP transceivers
Hardware installation
Figure 2: Location of FortiGate-5001FA2-LENC RAM DIMM slots
3
Insert each RAM DIMM perpendicular to the RAM DIMM slots. Push the DIMM
firmly into place using the minimum amount of force required. When the DIMM is
properly seated, the socket guide posts click into place.
Do not use excessive force when installing a DIMM.
The RAM slots allow only one alignment of each RAM DIM. If you cannot lock the
locking levers the DIM is not aligned correctly or is in upside-down.
Installing SFP transceivers
The FortiGate-5001FA2-LENC board ships with four SFP transceivers that you
must install for normal operation of the FortiGate-5001FA2-LENC board. The SFP
transceivers are inserted into cage sockets numbered 1 to 4 on the
FortiGate-5001FA2-LENC front panel. You can install the SFP transceivers before
or after inserting the FortiGate-5001FA2-LENC board into a FortiGate chassis.
JP3
JP2
JP1
RAM DIMM
slots
Front Faceplate
Note:
Cage slots 1 and 2 are rotated 180 degrees. Install the transceivers in slots 1 and 2
inverted compared to the orientation of the transceivers in slots 3 and 4.