background image

FortiFone - FON-D72 User Guide

Summary of Contents for FortiFone-FON-D72

Page 1: ...FortiFone FON D72 User Guide...

Page 2: ...ort fortinet com FORTINET TRAINING CERTIFICATION PROGRAM https www fortinet com support and training training html NSE INSTITUTE https training fortinet com FORTIGUARD CENTER https fortiguard com END...

Page 3: ...oyment 10 Estimating number of base stations based upon handsets 10 Estimating number of base stations based upon area 11 Calculating base station layout and measurements 12 Base station clusters 12 S...

Page 4: ...f the FortiFone FON D72 User Guide 2020 11 25 Updated Estimating number of base stations based upon handsets on page 10 Removed references to version 6 0 0 The version number is not required for this...

Page 5: ...ne features l Up to 8 concurrent calls per base up to a maximum of 100 l Up to 8 handsets per base up to a maximum of 100 l Supports up to 30 FON D72 B bases increasing the amount of calls handsets an...

Page 6: ...e of the base l Orange the role is DECT Manager l Green the role is Base l Slow flashing orange active calls on the DECT Manager 3 DECT LED Indicates the power status of the base station l Green DECT...

Page 7: ...Introduction Requirements A FON D72 configuration requires the following l 1 x FON D72 M l 1 x FON D72 B l 1 x FON D71 H FortiFone FON D72 User Guide 7 Fortinet Technologies Inc...

Page 8: ...ion l Setting up the phone Mounting the base station The base station can be wall mounted using two screws set 59 mm apart The base station may be mounted upright A sideways B or on the ceiling C The...

Page 9: ...xtensions on FortiVoice 2 On the FON D71 H handsets press the Reg softkey The handsets will display their name and extension number on screen For use as an external extension To configure as an extern...

Page 10: ...stations based upon handsets The following requirements must be considered when estimating how many base stations are needed and deciding where they should be placed l DECT radio coverage of the enti...

Page 11: ...ibuted over the site to be covered the traffic volume must be calculated for each area offices hotspots stairwells to determine the number of base stations that need to be installed Estimating number...

Page 12: ...ract with the base station History and Directory Load Balancing If the current base station is overloaded with active DECT or media connections the DECT connection is set up with a neighboring base st...

Page 13: ...ynchronization loss There can only be one base that is set to sync level 1 Keep this in mind when configuring the FON D72 in FortiVoice Correct Incorrect The multi cell network can be configured in nu...

Page 14: ...f environmental conditions For optimal signal strength it is best to first temporarily put base stations in place and measure the signal transmission The following table gives a general guideline on t...

Page 15: ...ns at corridor intersections like so l In a multi story building we recommend that you install additional base stations in the stairwells l Do not install the base in suspended ceilings cupboards or o...

Page 16: ...different building materials The following table displays the loss of DECT signal through the various materials Building materials Degree of attenuation Metal Very High Concrete walls High Brick wall...

Page 17: ...station D and F For the office room hotspot two additional base stations have been placed in parallel for optimal coverage and channel connections In this example the other hotspot is the After sales...

Page 18: ...lay the following RSSI Received Signal Strength Indication The recommended value is 27 to 85 dBm For guaranteed call quality and interference free handover a reading of 80 dBm To guarantee synchroniza...

Page 19: ...our measurement log The following image presents an example planning drawing The following table presents an example of measurement log results in dBm 100 for the above planning drawing Measuring poin...

Page 20: ...synchronize we recommend that the signal value between the base stations be kept above 85 dBm For this procedure 1 Leave the first level base station at the planned position Take the measuring handset...

Page 21: ...lts display that the signal strength is sufficient for synchronization everywhere Base station F and D can only receive base station E with sufficient quality and base station B C and E can only recei...

Page 22: ...ng dedicated base stations in the stairwells As shown here base station M has been added into the planning drawing in the stairs In this configuration also measure the signal strength within the stair...

Page 23: ...1 On the Extensions page of the FortiVoice interface ensure the MAC address is correctly entered and the Phone Type is FortiFone D72 Save your configuration and reboot the phone 2 If your phone is an...

Page 24: ...inet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified...

Reviews: