Deployment
The following table presents an example of measurement log results (in dBm/100%) for the above planned base station
positions:
Measuring
point
Base A
Base B
Base C
Base D
Base E
Base F
A
-37
-39
-61
B
-35
-47
C
-40
-45
-68
D
-53
E
-60
-70
-66
-50
-60
F
-60
These results display that the signal strength is sufficient for synchronization everywhere. Base station
F
and
D
can only
receive base station
E
with sufficient quality, and base station
B
,
C
and
E
can only receive base station
A
with sufficient
quality.
With this example, a sensible sync level hierarchy would be:
Sync Level 1:
Base station A
Sync Level 2:
Base stations B, C and E
Sync Level 3:
Base stations D and F