![Fortinet FortiCam CD51 Mounting Manual Download Page 12](http://html1.mh-extra.com/html/fortinet/forticam-cd51/forticam-cd51_mounting-manual_2322104012.webp)
12
Pendant cap
The pendant cap FortiCam-CD5-Mount-PCP allows combining FortiCam CD51/55 cameras with threaded mounting
accessories like pendant arm or drop ceiling tubes.
Options include:
Wall mount in combination with Pendant Arm FortiCam-FD50-Mount-PDT (SKU: FCM-FD5-PDT).
Optionally with junction box FortiCam-FB50-Mount-JBX
(SKU: FCM-FB5-JBX).
Drop
ceiling mount on COTS ¾” EMT tubing
1. Use the Mounting guide for FortiCam FD50 for instructions on how to mount the pendant
arm with or without the junction box to a wall.
https://docs.fortinet.com/product/fortirecorder/hardware
2. Screw pendant cap into pendant arm and secure with worm screw.
3. Cover the remaining visible thread with the white silicone ring.
4. Attach the mounting plate to the pendant cap with two of the supplied machine bolts (M4
x 10mm) using opposing FT1 positions.
5. Open camera housing using the three cover screws without removing the protective wrap
from the lens.
6. Connect the cable with the camera optionally using the waterproof connector. Tug the
connector into the pendant cap.
7. Place the camera on the mounting plate so the sockets fit into the matching recesses on
the camera bottom.
8. Fasten the camera with two of the supplied machine bolts (M4 x 10mm) to the sockets.
9.
Adjust the camera’s pan, tilt, and rotation angle.
10. Replace the dry pack found inside the camera with the fresh one from the protective
pouch in the box. Ensure no moisture gets trapped inside the camera.
11. Ensure the inside of the dome cover is free of dust and particles by gently wiping the
inside with a clean lint free cloth or blowing the dust away.
12. Install the dome cover and remove the protective wrap.