background image

11

5-Bluetooth

Steady Green: BLE scanning enabled.

No light: Neither BLE advertisement nor BLE scanning enabled.

Blinking Green: BLE advertisement or BLE scanning in progress.

4-WiFi

No light: Powered Off

Blue: Only 2.4GHz radio is up.

Blinking Blue: Data Tx/Rx on 2.4GHz Radio and only 2.4GHz Radio is up.

Orange: Only 5GHz radio is up.

Blinking Orange: Data Tx/Rx on 5GHz Radio and only 5GHz Radio is up.

Green: Both 2.4GHz Radio and 5Ghz Radio are working.

Blinking Green: Data Tx/Rx on both 2.4GHz Radio and 5GHz Radio.

Blinking Green and Orange: Data on 5GHz radio and both 2.4GHz Radio and 5GHz Radio are up.
Blinking Green and Blue: Data on 2.4GHz radio and both 2.4GHz Radio and 5GHz Radio are up.

1-Power

Steady Green: Power On

No light: Power Off

Blinking Green: Booting Up or Downloading Firmware.

2, 3-LAN1 and LAN2

No light: Link Down

Green: Connected at 1000Mbps.

Blinking Green: Data transmitting at 1000Mbps.

Yellow: Connected at 100Mbps.

Summary of Contents for FortiAP FAP-U321EV

Page 1: ...FortiAP FAP U321EV FAP U323EV Quick Start Guide ...

Page 2: ...323EV QuickStart Guide FAP U323EV Box Includes 5 GHz Antennas 3 2 4 5 GHz Antennas 3 5 GHz 5 GHz 5 GHz 5 GHz Recessed Tile T rail Bracket 2 Sizes Wall Ceiling Mount Standard Tile T rail Bracket 2 Sizes 1 Rubber Pads 4 ...

Page 3: ...FAP U321EV Box Includes FAP U321EV QuickStart Guide Wall Ceiling Mount Standard Tile T rail Bracket 2 Sizes Recessed Tile T rail Bracket 2 Sizes 2 Screws 16 Rubber Pads 4 ...

Page 4: ...ed on a ceiling using the provided ceiling mounting bracket To attach the unit to a ceiling wall using the mounting hardware 1 Slide and attach the ceiling mount bracket to the bottom cover of the FortiAP unit If extra space is required to accommodate drop ceiling tiles use the taller ceiling mount bracket 3 Ceiling Bracket Install Slide Direction ...

Page 5: ... against the ceiling t rail and push the FortiAP unit onto the ceiling until it snaps into place The unit can be removed from the bracket by pressing on the bracket tab and sliding the device out Four Holes for Ceiling Wall Mounting Ceiling T Rail 4 ...

Page 6: ...ts are included both standard and recessed ceiling mount brackets come in sizes 1 43cm 9 16in and 2 38cm 15 16in To protect your device from unauthorized removal use the Kensington Security Slot to attach a cable lock not included 5 ...

Page 7: ...ss the 2 4GHz radio signals and the 5G antennas to access the 5GHz radio signals To use both radio frequencies concurrently use all six WiFi antennas Installing the WiFi Antennas 1 Insert the antenna base firmly into the appropriate antenna mount 2 Securely hand tighten the fastening collar 3 Repeat for the remaining antennas 6 ...

Page 8: ...5 GHz 5 GHz 5 GHz 2 4 GHz 2 4 GHz 2 4 GHz A3 2 4 5G Antennas 7 Use the 2 4 5G and 5G antennas on the ports indicated above A2 5G A1 2 4 5G A6 5G A5 2 4 5G A4 5G ...

Page 9: ...All 5G antennas and 2 4 5G antennas are vertically oriented AP Mounting and Antenna Position 8 ...

Page 10: ... Ethernet port with Power over Ethernet PoE Powered Device PD support Power 12V 2 5A Console Port RJ 45 Optional management computer connection Provides access to the Command Line Interface CLI USB Port USB A 9 Serial Baud Rate 115200 ...

Page 11: ...LED Status 10 ...

Page 12: ... Radio and only 5GHz Radio is up Green Both 2 4GHz Radio and 5Ghz Radio are working Blinking Green Data Tx Rx on both 2 4GHz Radio and 5GHz Radio Blinking Green and Orange Data on 5GHz radio and both 2 4GHz Radio and 5GHz Radio are up Blinking Green and Blue Data on 2 4GHz radio and both 2 4GHz Radio and 5GHz Radio are up 1 Power Steady Green Power On No light Power Off Blinking Green Booting Up o...

Page 13: ...ximum TX power of 20dBm Caution Do not use any PoE injectors that are not IEEE 802 3af or 802 3at compliant as they may damage your device To connect the FortiAP unit 1 Insert an Ethernet cable into the LAN1 or LAN2 port of the FortiAP unit 2 Insert the other end of the Ethernet cable into your switch 3 If you are not using PoE connect the DC plug of the optional power adapter into the DC power ja...

Page 14: ...Recommended Operating Power The recommended operating power for FAP U32xEV is 20dBm in the 2 4GHz band and 20dBm in the 5 0GHz band 13 ...

Page 15: ...rted Controller Types FAP U323EV and FAP U321EV are compatible with FortiWLC enterprise wireless LAN controllers integrated FortiGate enterprise firewall LAN controllers and FortiCloud controllers The FortiAP boots up with the FortiWLC AP image factory default and tries to discover the supported controllers The FortiAP connects to the controller that is first discovered If the FortiGate or the For...

Page 16: ...twork and subnet as the FortiWLC or if the unit is directly connected to the FortiGate LAN Controller or is on the same layer 3 network and subnet as the FortiGate or FortiCloud controller If the FortiAP wireless controller s IP address cannot be determined using Zero Configuration mode or if the network uses static IP addresses it can be configured to use a static IP address Zero Configuration 15...

Page 17: ...cedure and requests an IP address from the DHCP server 2 If the IP address is retrieved successfully the FortiAP enters discovery mode to locate a Controller The discovery modes for the FortWLC controller are DHCP option 43 DHCP option 138 Mesh PNP The discovery modes for FortiGate controller are DHCP option 138 Multicast Broadcast Zero Configuration 16 ...

Page 18: ...The discovery modes for FortiCloud controller are Auto FortiCloud 3 Verify that the FortiAP has successfully connected to the controller in the FortiWLC FortiCloud FortiGate WebUI Zero Configuration 17 ...

Page 19: ...tmask netmask ip address gateway gateway ip address 4 FortiWLC only To discover the controller type ip config l2l3 l2only l2preferred l3only l3preferred 5 To configure a designated wireless controller s IP address type ip config controller name controller ip address 6 Save the configuration by typing ip config save 7 Unplug the FortiAP unit and plug it back in order for the configuration to take e...

Page 20: ... harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Page 21: ...t isotopically radiated power e i r p is not more than that necessary for successful communication Ce dispositif a été conçu pour fonctionner avec une antenne ayant un gain maximal de 5 2 dBi pour 2 4 GHz et 7 3 dBi pour 5GHz Une antenne ayant un gain supérieur sont strictement interdites par la réglementation d ISED L impédance d antenne requise est de 50 ohms Conformément à la réglementation d I...

Page 22: ...te Agência Nacional de Telecomunicações ANATEL Brazil Este produto não é apropriado para uso em ambientes domésticos pois poderá causar interferências eletromagnéticas que obrigam o usuário a tomar medidas necessárias para minimizar estas interferências Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados E...

Page 23: ... of blades CPUs or databases on the single blade CPU or database on which Fortinet installed the Software or for stand alone Software solely on a single computer running a validly licensed copy of the operating system for which the Software was designed unless and except set forth in the published documentation otherwise or in the case of blades CPUs or databases on a single blade CPU or database ...

Page 24: ...guration or return shipment and handling fees and costs and Fortinet shall have no obligation related thereto Such repair or replacement will be rendered by Fortinet at an authorized Fortinet service facility as determined by Fortinet The replacement Hardware need not be new or of an identical make model or part Fortinet may in its discretion replace the defective Hardware or any part thereof with...

Page 25: ...s Export Administration Regulations and other import and export laws diversion contrary to United States law and regulation is prohibited You agree to comply with all applicable international and national laws that apply to the Products as well as end user end use and destination restrictions issued by U S and other governments For additional information on U S export controls see www bis doc gov ...

Page 26: ...nder the terms of this General Public License The Program below refers to any such program or work and a work based on the Program means either the Program or any derivative work under copyright law that is to say a work containing the Program or a portion of it either verbatim or with modifications and or translated into another language Hereinafter translation is included without limitation in t...

Page 27: ...uld not permit royalty free redistribution of the Program by all those who receive copies directly or indirectly through you then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program If any portion of this section is held invalid or unenforceable under any particular circumstance the balance of the section is intended to apply and th...

Page 28: ...idered independent and separate works in themselves then this License and its terms do not apply to those sections when you distribute them as separate works But when you distribute the same sections as part of a whole which is a work based on the Library the distribution of the whole must be on the terms of this License whose permissions for other licensees extend to the entire whole and thus to ...

Page 29: ...ary and explaining where to find the accompanying uncombined form of the same work 8 You may not copy modify sublicense link with or distribute the Library except as expressly provided under this License Any attempt otherwise to copy modify sublicense link with or distribute the Library is void and will automatically terminate your rights under this License However parties who have received copies...

Page 30: ...conditions are incompatible with these write to the author to ask for permission For software which is copyrighted by the Free Software Foundation write to the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all derivatives of our free software and of promoting the sharing and reuse of software generally 1...

Page 31: ...ment Library Up to date versions of Fortinet publications for the entire family of Fortinet products http docs fortinet com Training Services Course descriptions availability schedules and location of training programs in your area http www fortinet com training Technical Discussion Forums Communicate with other customers and Fortinet partners about Fortinet products services and configuration iss...

Reviews: