LED

State

Description

1

HDD (top)

Flashing Amber

Hard drive read or write activity . 

2

Status (middle)

Off

System is normal .

Red

System failure .

3

Power (bottom)

Green

The appliance is receiving power .

4

Ethernet Ports  
Activity (left)

Flashing Amber

Port is transmitting & receiving data . 

Off

No link detected .

Ethernet Ports  
Speed (right)

Green

Port is connected at 1 Gbps .

Amber

Port is connected at 100 Mbps .

Off

Port is connected at 10 Mbps or is not in use .

5

SFP Ports  
Activity (left)

Flashing Amber

Port is transmitting & receiving data . 

Off

No link detected .

SFP Ports  
Speed (right)

Green

Port is connected at 1 Gbps .

Off

No link detected .

6

SFP+ Ports  
Speed (left)

Green

Port is connected at 1 Gbps or 10 Gbps .

Off

No link detected .

SFP+ Ports 
Activity (right)

Green

Link detected .

Flashing Green

Port is transmitting & receiving data .

Off

No link detected .

Cautions and warnings

Environmental specifications

Ambient operating temperature: 0°C to 40°C 

Rack Mount Instructions

 - The following or similar rack-mount instructions are 

included with the installation instructions:

Instructions de montage en rack

 - Les instructions de montage en rack suivantes 

ou similaires sont incluses avec les instructions d’installation:

Elevated Operating Ambient

 - If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack environment may be greater than 
room ambient . Therefore, consideration should be given to installing the equipment 
in an environment compatible with the maximum ambient temperature (Tma) 
specified by the manufacturer .

Température ambiante élevée

 – S’il est installé dans un rack fermé ou à unités 

multiples, la température ambiante de fonctionnement de l’environnement du rack 
peut être supérieure à la température ambiante de la pièce . Par conséquent, il est 
important d’installer le matériel dans un environnement respectant la température 
ambiante maximale (Tma) stipulée par le fabricant .

Reduced Air Flow

 - Installation of the equipment in a rack should be such that the 

amount of air flow required for safe operation of the equipment is not compromised .

Ventilation réduite

 – Installation de l’équipement dans un rack doit être telle que la 

quantité de flux d’air nécessaire au bon fonctionnement de l’équipement n’est pas 
compromise .

Mechanical Loading

 - Mounting of the equipment in the rack should be such that 

a hazardous condition is not achieved due to uneven mechanical loading .

Chargement Mécanique

 – Montage de l’équipement dans le rack doit être telle 

qu’une situation dangereuse n’est pas lié à un chargement mécanique inégal .

Circuit Overloading 

- Consideration should be given to the connection of the 

equipment to the supply circuit and the effect that overloading of the circuits might 
have on overcurrent protection and supply wiring . Appropriate consideration of 
equipment nameplate ratings should be used when addressing this concern .

Surtension

 – Il convient de prendre l’ensemble des précautions nécessaires lors 

du branchement de l’équipement au circuit d’alimentation et être particulièrement 
attentif aux effets de la suralimentation sur le dispositif assurant une protection 
contre les courts-circuits et le câblage . Ainsi, il est recommandé de tenir compte du 
numéro d’identification de l’équipement .

Reliable Earthing 

- Reliable earthing of rack-mounted equipment should be 

maintained . Particular attention should be given to supply connections other than 
direct connections to the branch circuit (e .g . use of power strips) .

Fiabilité de la mise à la terre 

– Fiabilité de la mise à la terre de l’équipement 

monté en rack doit être maintenue . Une attention particulière devrait être accordée 
aux connexions d’alimentation autres que les connexions directes au circuit de 
dérivation (par exemple de l’utilisation de bandes de puissance) .

Summary of Contents for FortiADC 400F

Page 1: ...Application Delivery Controller FortiADC 400F QuickStart Guide...

Page 2: ...ment warranty 15 Power Cable Console Cable 4 Rubber Feet 8 Bracket Screws Ethernet Cable 2 Rack Mount Ears 2 Grounding Screws FortiADC 400D QuickStart Guide QuickStart Guide Package contents The box s...

Page 3: ...is can cause damage to the cables cable connectors and optical interfaces It may also prevent the transceiver from latching correctly into the socket Note Installing and removing SFP transceivers can...

Page 4: ...all Switch Administrator Servers FortiADC 4 Press the transceiver firmly into the cage socket with your thumb until it clicks indicating that it is latched 5 To verify that the transceiver is latched...

Page 5: ...8 Parity None Stop bits 1 Flow control None 3 Press Enter on your keyboard to connect to the CLI Shutting down Always properly shut down the FortiADC appliance s operating system before turning off th...

Page 6: ...8 4638 Fax 1 408 235 7737 Email register fortinet com Ports LEDs 1 2 3 4 5 6 Interface Type Protocol Description 1 Console RJ 45 RS 232 Serial Connection to the managment computer 9600 bps access to t...

Page 7: ...t il est important d installer le mat riel dans un environnement respectant la temp rature ambiante maximale Tma stipul e par le fabricant Reduced Air Flow Installation of the equipment in a rack shou...

Page 8: ...emely low air pressure it may result in leakage of flammable liquid gas or an explosion WARNUNG Lithium Batterie Achtung Explosionsgefahr bei fehlerhafter Batteriewechsel Ersetzen Sie nur den gleichen...

Page 9: ...scrites dans le R glement sur le brouillage radio lectrique dicte par le minist re des Communications du Canada European Conformity CE EU This is a Class A product In a domestic environment this produ...

Page 10: ...om you but does not agree to the restrictions and obligations contained in this Agreement and therefore wishes to return the Product s as provided for in this Agreement Notwithstanding anything to the...

Page 11: ...ine readable copy please send your written request along with a check in the amount of US 25 00 to General Public License Source Code Request Fortinet Inc 899 Kifer Rd Sunnyvale CA 94086 USA In order...

Page 12: ...oundation Inc 59 Temple Place Suite 330 Boston MA 02111 1307 USA TERMS AND CONDITIONS FOR COPYING DISTRIBUTION AND MODIFICATION 0 This License Agreement applies to any software library or other progra...

Page 13: ......

Reviews: