WIRING
•
Max.4 door stations can be connected to the system.
• Ensure to set the correct address for each door station, Refer to Page 7 for more details
about the address setting of door stations.
•
Please refer to FTDEV1VD instructions for more details.
Connecting Basic One-to-one
Connecting Multi Door Stations
BUS(IM) BUS(DS)
-
+
L1 L2 PL S+ S-
ID=0
Code=1, DIP6=on
1 2 3 4 5 6
ON
DIP
L2
L1
DIP Switches
FTDEV1PSU
AC~
230VAC
230VAC
FTDEV1VD
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
FTDEV1PSU8
AC~
ID=0
1
st
door station
ID=1
2
nd
door station
ID=2
3
rd
door station
ID=3
4
th
door station
L1 L2 PL S+ S-
L1 L2 PL S+ S-
L1 L2 PL S+ S-
L1 L2 PL S+ S-
To monitors
•
The door station work in
Standard
mode in this situation. Refer to Page 8 in detail.
•
The door station is also compatible with other monitors which are available.
•
If additional monitors are to be connected then the kit PSU (FTDEV1PSU) will need to be
changed to an FTDEV1PSU8.
• If the FTDEV1PSU8 is used then up to 8 monitors can ring all 8 monitors, but only 4 will dis
-
play the cameras image when ringing.