fortessa FTDEAH Instruction Manual Download Page 6

4

B, Cable to door stations/modules

RVV2x1.0 

(

AWG18

)

2

mm

                                                                   

Part 2 Connection

2.1  Cable requirements:

A, Cable  from door station to modules/ indoor phones

RJ45 Port

CAT-5/E cable

       

Please follow TIA/EIA-568B Standard for CAT-5(E) cables to avoid interference.

Wires

Type(size)

Distance

Wire resistance

Door station to module

Modules to indoor phones

FTP-5E(1.5)

UTP-5(0.75)

RVV(2X1.0)

50m

10

Ω

10

Ω

<

30m 

2.2 Cables and distance

        

30m 

<

Min. gap:

50cm, between low voltage and high voltage.

2.3

 

Terminals

EXT

 

KEY

12V

 

G

 

DATA

SW21

SW22

SW23

SW24

ADDR0

ADDR1

ADDR2

ADDR3

12V

12V

DATA

ALM

 

G

 

UL

 

G

COM

  

NC

  

NO

12V+  12V-  L+  L-

Jp3

JP1

JP2

Jp4

JP8

Jp6

JP51

JP21

12V-     AU   32VIN    V-

12V+ SGND ETRXD V+

R-    T+   A+    VM-

R+   A-    T-     VM+

POWER    UNLOCK

A, Door station Model FTDEPC4 

B, Assistant door panel Model FTDEP4, FTDEP8

RJ45 port to isolation module.

Standby

.

Terminals to power supply & e-lock(power type).

Terminals to e-lock (signal type).



Terminals to EXIT push button. 
Terminals between door station FTDEPC4 and assistant door panels.
Jumper couplers for coding assistant door panels.

Power supply to modules

Module

 

to

 

next

 

module

FTP-5E(1.5)

<

40m

(Please see details in 3.3.)

10

Ω

Summary of Contents for FTDEAH

Page 1: ...MULTIWAY 2 12 WAY DOOR ENTRY SYSTEM FTDEVM2 12 Instruction Rev01 ...

Page 2: ...Part 3 System programming Part 4 Operation 4 1 Operation on door station 4 2 Operation on indoor phone 3 1 Call button numbers and address 3 2 Indoor phone address setting 5 1 Installation of door station 3 3 Isolation module 5 2 Installation of Indoor phone handset 5 3 Installation of isolation module 5 4 Installation of power supply 1 3 1 3 4 5 4 10 9 11 9 10 9 12 12 13 14 15 CONTENTS Page 14 15...

Page 3: ... call button No 4 button name tag colour camera Model FTDEVM7 Emergency button Standby Monitor button Unlock button Answer button Speech volume adjustor Image adjustors Microphone Speaker M Image adjustors Microphone Speaker Power indicator Emergency button Monitor button Unlock button Answer button Speech volume adjustor Model FTDEVM4 ...

Page 4: ...ne Coil cord Alarm activated button Model FTDEAH Power terminals Rj45 port to door station RJ45 ports to indoor phones Power indicator RJ45 ports to next module optional Isolation module FTDEIM Power output terminals Power indicators Power input terminals Power supply 12V 32V FTDEPSU12 FTDEPSU32 2 ...

Page 5: ...udio distortion Standby current Working current Power supply Environment temperature 4 3 7 TFT LCD colour TFT LCD 660x234 pixel 4 3 1440x234 pixel 7 1V 75Ω P P 25dB 7 60mA 260mA DC32V 10 DC12V 10 25 55 3 1 2 3 Isolation module 1 2 4 Power supplies Working voltage Working current Video input Video output Audio output Environment temperature DC12V DC32V 200mA 0 7 4 routes Ω P P P P Ω P P 40 70 V 1 2...

Page 6: ...igh voltage 2 3 Terminals EXT KEY 12V G DATA SW21 SW22 SW23 SW24 ADDR0 ADDR1 ADDR2 ADDR3 12V 12V DATA ALM G UL G COM NC NO 12V 12V L L Jp3 JP1 JP2 Jp4 JP8 Jp6 JP51 JP21 12V AU 32VIN V 12V SGND ETRXD V R T A VM R A T VM POWER UNLOCK A Door station Model FTDEPC4 B Assistant door panel Model FTDEP4 FTDEP8 RJ45 port to isolation module Standby Terminals to power supply e lock power type Terminals to e...

Page 7: ...ams 2 4 1 Basic component diagram A For FTDEV1 4 and FTDEV5 8 kit Video door station Assist door panel RVV2x1 0 2 mm RVV2x1 0 2 mm 3wires Video indoor phone CAT5E CAT5 Isolation module Isolation module PSU 32 PSU 12 5 ...

Page 8: ...B For FTDEV9 12 kit Video door station Assist door panel RVV2x1 0 2 mm RVV2x1 0 2 mm 3wires Video indoor phone CAT5E CAT5 Isolation module Isolation module Isolation module PSU 32 PSU 12 6 PSU 12 ...

Page 9: ...P8 JP6 JP 51 Jp21 12V AU 32VIN V 12V SGND ETRXD V R T A VM R A T VM POWER UNLOCK EXT KEY 12V G DATA SW21 SW22 SW23 SW24 ADDR0 ADDR1 ADDR2 ADDR3 Isolation module SGNG 32V G 12V SOUT POUT INPUT OUT 4 OUT 3 OUT 2 OUT 1 Isolation module SGNG 32V G 12V SOUT POUT INPUT OUT 4 OUT 3 OUT 2 OUT 1 To other indoor phones To other indoor phones Video indoor phone All terminals of N L and have to be connected t...

Page 10: ...12V SGND ETRXD V R T A VM R A T VM POWER UNLOCK Wiring diagrams of lock releases and electromagnetic locks Door station FTDEPC4 COM NC NO Electromagnetic lock 12V 12V DATA ALM G UL G COM NC NO 12V 12V L L JP3 JP1 JP2 JP4 JP8 JP6 JP51 JP21 12V AU 32VIN V 12V SGND ETRXD V R T A VM R A T VM POWER UNLOCK Power supply Touch N C COM _ DIODE Break glass to release This device comes with a varistor A vari...

Page 11: ... following table Please arrange the power supply for projects accordingly Power supply FTDEPSU12 FTDEPSU32 Audio indoor phone Video indoor phone 20pcs 16pcs 16pcs 4pcs 4pcs 12V 12V DATA ALM G UL G COM NC NO 12V 12V L L JP3 JP1 JP2 JP4 JP8 JP6 JP51 JP21 12V AU 32VIN V 12V SGND ETRXD V R T A VM R A T VM POWER UNLOCK PSU 12 Isolation module ...

Page 12: ... No Address code No 0 SW1 SW2 SW3 SW4 0005 0012 No 0005 No 0006 No 0007 No 0008 No 0009 No 0010 No 0011 No 0012 3 2 Indoor phone address setting 3 2 1 Wiring Prepare the cables and wire the necessary devices with the enclosed terminal connectors as the following diagram If there is any assistant door panel please connect it also Video indoor phone CALL 12VIN G AF ETRXD 32VIN V V ALM 12V 12V DATA A...

Page 13: ...ave the functions of audio video signal distribution amplification and mal function isolation Each module supports up to 4 indoor phones Indoor phones are workable in 50 meters from their modules There are jumper couplers in the back of the modules as the following figures Please arrange them according to different applications 1F 2F 1M 100 1F 2F 1M 100 1F 2F 1M 100 1F 1M default 1F 100 2F 100 3 3...

Page 14: ...econds If you need to end the communication please push button 4 2 Operation on indoor phone 4 2 1 Answer Push the button as the following figures 4 2 2 Release doors While at intercom status please push button to release the door as the following figures 4 2 3 Video surveillance lease p surveil the door station P ush button when need to During surveillance status you could push button and talk to...

Page 15: ...more than 2 seconds when the indoor phone is idle and then push the button again and again until you get a favourite ring tone There are more than 10 melody ring tones 2 4 2 4 Family intercom If there are 2 or more indoor phones in your family you could use an indoor phone to call another by pushing button and then button For longer time to adjust image quality you may push button then push button...

Page 16: ...d from dust 14 a Cut out a rectangular hole as the installation size 104x214x50mm on a suitable position and then fix the box in it with cement or screws b Take off the screws and then the frame c Put the rubber seal on the back of door panel d Put the door panel into the box and fix it with the screws after connection e Put the frame on the door panel and fix it with the screws Dismantle Press th...

Page 17: ...e wall after connection as Figure B a Measure the gap between two installation holes b Install the expansion plugs and screws in the wall as Figure A Please leave the screws raised a proper length from the wall 5 2 2 Install audio handset 5 3 Installation of isolation module 1 2 3 Fix the rail Hang the box on the rail Pull out the latch push the box on the rail and then release the latch 5 4 Insta...

Page 18: ...Notes ...

Page 19: ...carefully checked prior to publication However no responsibility can be accepted by Challenger Security Products for any misinterpretation of these instructions Distributed by CHALLENGER SECURITY PRODUCTS 10Sandersons Way Blackpool FY4 4NB Technical helpline 01253792898 Email enquiries challenger adivision co uk Website www challenger co uk FTDEVM2 12 Instruction Rev01 ...

Reviews: