Premium Hot Towel Warmer Operation Manual
Congratulations on your purchase of the ForPro Premium Hot Towel Warmer. Please read
the instructions and safety tips before use. Your Hot Towel Warmer comes with a two-year
limited warranty. If for any reason you need service, please call 800-520-6000.
Product Specification
Rated Volume:
23L
Rated Power:
200W
Rated Voltage:
110V
Rated Frequency:
60Hz
Set Temperature:
180°F
Towel Load:
24 Facial-Sized Towels
External Dimensions: 17.75”W x 11”D x 14”H
Inside Dimensions: 14.5”W x 7.5”D x 9.75”H
Components
Before Operation
• Be sure to remove all packing material before use.
• Place the unit on a well ventilated, flat, sturdy surface away from heat sources. The unit should
not be used in the immediate vicinity of water (such as bathtub, washbowls, etc.) where the
likelihood of immersion may occur. Keep at least 30mm away from walls and other objects.
• Plug cord into a 110V power outlet.
• Remove the wire basket and set aside.
Operation
1. Run towels briefly under water.
2. Wring out excess water from the towels. Towels should be damp, not soaked. You may
need to wring out several times.
3. Fold or roll towel and place towels into the wire basket. Do not overload the wire basket or
directly place towels into the towel warmer.
4. Insert the basket with towels into towel warmer.
5. Close the door firmly.
6. Press the power switch to the lock position. The indicator near the switch will be on to
show that the towel cabinet has started heating with the UV light on. In about 30 minutes,
the temperature inside the cabinet will heat up to approximately 180°F and will be kept
automatically. (When the temperature reaches 167°F the UV light will turn off automatically
and if the temperature drops to 140°F it will automatically turn back on. It is normal for
UV light to alternate on and off.) Allow 30 minutes of operation for UV sterilization to be
complete. Avoid opening cabinet before towels are heated.
7. lf a towel is needed for use, press the power switch and wait for the indicator to turn off
to open the cabinet door. Stay a safe distance from cabinet door opening to avoid being
burned by high temperature steam from the cabinet. Remove towels with tongs or heat-
resistant gloves.
8. Towels may be too hot to apply immediately, and caution should be used before applying
to the face or body.
Maintenance
1. Turn OFF the unit.
2. Unplug the cord from the outlet.
3. Wait for contents to cool before handling. Contents may be hot. Remove the wire basket
and towels. Set the wire basket aside to dry.
4. With a soft cloth, wipe down the internal surfaces. Do not use harsh chemicals or abrasives.
To clean exterior, use a soft cloth and mild soap.
5. Pull the drip tray forward and empty contents. Set the drip tray aside to dry.
Replacing the UV Bulb
1. Turn OFF the unit.
2. Unplug the cord from the outlet.
3. Remove all the screws on the back panel
and open the back panel.
4. You can see the white cotton after opening
the back panel. See Fig. 1.
5. Take out the white cotton back, you can see
the position of the lamp. See Fig. 2.
6. Unplug both lines. See Fig. 3.
7. Loosen the screws on the small box (the screws are connected to the inside of the liner and
can be screwed out from the inside of the liner). See Fig. 4a & 4b.
Power Switch
Power
Indicator Light
Wire basket
Water Drip Tray
Cabinet Leg
Cabinet Door
23A, 46A towel cabinet replacement lamp steps:
1. Remove all the screws on the back panel and open the back panel.
2. You can see the white cotton after opening the back panel.
3. Take out the white cotton back, you can see the position of the lamp, as
shown
4. Unplug both lines
Fig. 1
23A, 46A towel cabinet replacement lamp steps:
1. Remove all the screws on the back panel and open the back panel.
2. You can see the white cotton after opening the back panel.
3. Take out the white cotton back, you can see the position of the lamp, as
shown
4. Unplug both lines
Fig. 2
23A, 46A towel cabinet replacement lamp steps:
1. Remove all the screws on the back panel and open the back panel.
2. You can see the white cotton after opening the back panel.
3. Take out the white cotton back, you can see the position of the lamp, as
shown
4. Unplug both lines
Fig. 3
5. Loosen the screw on the small box (the screw is connected to the inside
of the liner and can be screwed out from the inside of the liner)
6. On the right side of the box, you can see two screws, screw out the two
screws and open the small cover of the box.
7. Remove the old tube, put the new tube back inside the small box, close
the lid, and tighten the two screws on the lid.
5. Loosen the screw on the small box (the screw is connected to the inside
of the liner and can be screwed out from the inside of the liner)
6. On the right side of the box, you can see two screws, screw out the two
screws and open the small cover of the box.
7. Remove the old tube, put the new tube back inside the small box, close
the lid, and tighten the two screws on the lid.
Fig. 4a
Fig. 4b