background image

                Premium Hot Towel Warmer Operation Manual

Congratulations on your purchase of the ForPro Premium Hot Towel Warmer. Please read 

the instructions and safety tips before use. Your Hot Towel Warmer comes with a two-year 

limited warranty. If for any reason you need service, please call 800-520-6000.

Product Specification

Rated Volume: 

23L

Rated Power: 

200W

Rated Voltage: 

110V

Rated Frequency: 

60Hz

Set Temperature: 

180°F

Towel Load: 

24 Facial-Sized Towels

External Dimensions:  17.75”W x 11”D x 14”H 

Inside Dimensions:  14.5”W x 7.5”D x 9.75”H

Components

Before Operation

• Be sure to remove all packing material before use.
•  Place the unit on a well ventilated, flat, sturdy surface away from heat sources. The unit should 

not be used in the immediate vicinity of water (such as bathtub, washbowls, etc.) where the 

likelihood of immersion may occur. Keep at least 30mm away from walls and other objects.

• Plug cord into a 110V power outlet.
• Remove the wire basket and set aside.

Operation

1.  Run towels briefly under water.
2.   Wring out excess water from the towels. Towels should be damp, not soaked. You may 

need to wring out several times.

3.   Fold or roll towel and place towels into the wire basket. Do not overload the wire basket or 

directly place towels into the towel warmer.

4.   Insert the basket with towels into towel warmer.
5.  Close the door firmly.
6.   Press the power switch to the lock position. The indicator near the switch will be on to 

show that the towel cabinet has started heating with the UV light on. In about 30 minutes, 

the temperature inside the cabinet will heat up to approximately 180°F and will be kept 

automatically. (When the temperature reaches 167°F the UV light will turn off automatically 

and if the temperature drops to 140°F it will automatically turn back on. It is normal for 

UV light to alternate on and off.) Allow 30 minutes of operation for UV sterilization to be 

complete. Avoid opening cabinet before towels are heated. 

7.   lf a towel is needed for use, press the power switch and wait for the indicator to turn off 

to open the cabinet door. Stay a safe distance from cabinet door opening to avoid being 

burned by high temperature steam from the cabinet. Remove towels with tongs or heat-

resistant gloves.

8.   Towels may be too hot to apply immediately, and caution should be used before applying 

to the face or body. 

Maintenance

1.  Turn OFF the unit.
2.  Unplug the cord from the outlet. 
3.   Wait for contents to cool before handling. Contents may be hot. Remove the wire basket 

and towels. Set the wire basket aside to dry.

4.   With a soft cloth, wipe down the internal surfaces. Do not use harsh chemicals or abrasives. 

To clean exterior, use a soft cloth and mild soap.

5.   Pull the drip tray forward and empty contents. Set the drip tray aside to dry.

Replacing the UV Bulb

1.  Turn OFF the unit.

2.  Unplug the cord from the outlet. 

3.  Remove all the screws on the back panel  

and open the back panel.

4.  You can see the white cotton after opening 

the back panel. See Fig. 1.

 

5.  Take out the white cotton back, you can see 

the position of the lamp. See Fig. 2.

 

6. Unplug both lines. See Fig. 3.

7.  Loosen the screws on the small box (the screws are connected to the inside of the liner and 

can be screwed out from the inside of the liner). See Fig. 4a & 4b.

  

Power Switch

Power 
Indicator Light

Wire basket

Water Drip Tray

Cabinet Leg

Cabinet Door

23A, 46A towel cabinet replacement lamp steps: 

1. Remove all the screws on the back panel and open the back panel. 

2. You can see the white cotton after opening the back panel. 

 

3. Take out the white cotton back, you can see the position of the lamp, as 

shown 

 

4. Unplug both lines 

 

Fig. 1

23A, 46A towel cabinet replacement lamp steps: 

1. Remove all the screws on the back panel and open the back panel. 

2. You can see the white cotton after opening the back panel. 

 

3. Take out the white cotton back, you can see the position of the lamp, as 

shown 

 

4. Unplug both lines 

 

Fig. 2

23A, 46A towel cabinet replacement lamp steps: 

1. Remove all the screws on the back panel and open the back panel. 

2. You can see the white cotton after opening the back panel. 

 

3. Take out the white cotton back, you can see the position of the lamp, as 

shown 

 

4. Unplug both lines 

 

Fig. 3

 
5. Loosen the screw on the small box (the screw is connected to the inside 

of the liner and can be screwed out from the inside of the liner) 

 

6. On the right side of the box, you can see two screws, screw out the two 

screws and open the small cover of the box. 

 

7. Remove the old tube, put the new tube back inside the small box, close 

the lid, and tighten the two screws on the lid. 
 

 
5. Loosen the screw on the small box (the screw is connected to the inside 

of the liner and can be screwed out from the inside of the liner) 

 

6. On the right side of the box, you can see two screws, screw out the two 

screws and open the small cover of the box. 

 

7. Remove the old tube, put the new tube back inside the small box, close 

the lid, and tighten the two screws on the lid. 
 

Fig. 4a

Fig. 4b