Oven rack rail installation
Electrical
Your range must be electrically grounded in accordance with local codes or, in the absence of local
codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada,
electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1
and/or local codes.
The power supply must be the correct polarity. Reverse polarity will result in continuous sparking of
the electrodes, even after flame ignition. If there is any doubt as to whether the power supply has the
correct polarity or grounded, have it checked by a qualified electrician.
ELECTRICAL REQUIREMENTS
Electrical Supply
FFSGS6187-30 3600W
Grounded, 240 VAC, 60Hz
FFSGS6187-36 3600W
Grounded, 240 VAC, 60Hz
FFSGS6187-48 7025W
Grounded, 240 VAC, 60Hz
Service
Receptacle
4-prong grounding-type
PowerCord
3.9' (1.2m)
WARNING
Electrical grounding Instructions:
This range is equipped with a four-prong (grounding) plug
for your protection against shock hazard and should be plugged directly into a properly grounded four-prong
receptacle.
Do not
cut or remove the grounding pin from the plug.
2/C 8AWG+2/C 10AWG
12
Socket
FFSGS6187-60 7200W
Grounded, 240 VAC, 60Hz
Installation
Hang the rack to the side rails and push in slowly
Disassemble
Lift the rack up and pull out slowly until free of the side rails.