background image

   

                                                                 

DTSY1286E User Manual 

 

Shanghai Fengyilong Electronic Co,. Ltd.           

www.china-meters.com

        Email:[email protected]

                                                                                                                                                           

+86-21-60975591/ 60975592 

4.1.2 Display description 

·

Reverse each show an IC card is inserted, the display refer to the table below   

Explanation 

Number 

content 

form 

unit 

00 

Remaining electricity 

x x x x x x 

- x x x x x 

kWh 

01 

Total electrictity 

x x x x x x 

kWh 

02 

default value 

 

 

03 

Current power value 

x x x x x x 

04 

Power limit value

 

x x x x x 

05 

Overdraft electricity 

x x x x 

kWh 

06 

Recent purchase of electricity 

x x x x x 

kWh 

07 

table  number 

x x x x x x 

 

08 

The number of super-power pulses of 

electricity decimal 

xx    xx    xx 

 

4.1.3 Purchase kWh   

When insert IC card forward(iron chip on the left)into meter, purchase success will display

0

then shows the remaining energy (elect new share surplus energy in the table); 

If the meter displays "EX", indicates that the power purchase unsuccessful. 

4.1.4 Switch out: three cases may switch up 

a) the purchase of electricity consumption has been displayed "OFF D" at this time need 

to purchase closing; 

b)Electric power exceeds the set value, the display "OFF F" then click purchase card can 

be inserted to restore power, if more than 10 times you need a valid purchase order to 

restore power; 

c) cut electricity Kara Gate, display "OFF E" need to plug the card cut electric power is 

restored. 

4.1.5 Warning: When  power  is  equal  to  alarm  setting,  flashing  digital  display  remaining 

power, prompts the user to purchase. 

4.1.6 Electric back: Insert the card back power meter data read out, and then remove the 

data, you can re-open an account. 

 

5. Installation   

Meter installed in the indoor or outdoor meter box, installed base should be solid   

Set in a rugged fireproof walls, concrete mounting dimensions shown in diagram 

Reviews: