7.0. MAINTENANCE
Periodic maintenance is essential to maintain the effi-
ciency of your air conditioner.
Before performing any maintenance, disconnect the
power supply.
INDOOR UNIT
Anti-dust Filters
1)
Open the front panel (following the direction of the
arrows shown on the right).
2)
Holding the front panel open with one hand, remove
the air filter with the other.
3)
Clean the filter with water. If the filter is dirty with oil,
it can be washed in warm water not exceeding 45 °C
(113 °F). Leave to dry in a cool, dry place.
4)
Holding the front panel open with one hand, insert
the air filter with the other.
5)
Close the front panel.
The electrostatic and deodorant filter (if installed) can-
not be washed and must be replaced with new filters
every 6 months.
CLEANING THE HEAT EXCHANGER
1)
Open the front panel of the unit and unhooking it
from the hinges to make the cleaning easier.
2)
Clean the indoor unit with a cloth soaked in water no
warmer than 40 °C (104 °F) and neutral soap. Never
use aggressive solvents or detergents.
3)
If the air inlet and outlet of the outdoor unit are
clogged, remove any leaves or waste by hand and
remove the dust with a jet of air or a bit of water.
END OF SEASON MAINTENANCE
1)
Disconnect the automatic switch or the plug.
2)
Clean and replace the filters.
3)
On a sunny day, let the air conditioner run in
Fan
mode for several hours so that the inside of the unit
can dry completely.
Anti-dust filter
Summary of Contents for FA-H09-A20TL