![ForestAir FA-H09-A20TL Installation And Operation Manual Download Page 23](http://html1.mh-extra.com/html/forestair/fa-h09-a20tl/fa-h09-a20tl_installation-and-operation-manual_2319406023.webp)
23
6.0. INSTALLATION INSTRUCTIONS
Only persons and/or companies qualified and experienced in the installation, service and repair of refrig-
erant products should be authorized to carry out the work. The user must ensure that the person and/or
company who is to carry out the installation, servicing or repairs of this air conditioner has qualifications
and experience in refrigerant products.
█ 6.1. LOCATION RECOMMENDATIONS
INDOOR MURAL UNIT
▪ Install the indoor unit level on a solid wall that is not subject to vibration.
▪ The air inlet and outlet vents must not be blocked. The air must be able to reach all 4 corners of the room.
▪ Do not install the appliance near a source of heat, steam, or flammable gas.
▪ Install the unit near an electric socket or private circuit. Do not install the mural unit where it will be
exposed to direct sunlight.
▪ Install the unit where the connection between the indoor and the outdoor unit is as simple as possible.
▪ Install the appliance where it is easy to drain the condensed water.
▪ Check the unit operation regularly and leave the necessary space (as shown in the illustration below).
▪ Install the mural unit where the filter can be easily accessible.
Mounting plate
Water drain pipe
Sleeve
Condensed water drain pipe
Electrical cable
Insulating covering
15 cm
(6 in)
15 cm
(6 in)
15 cm
(6 in)
Summary of Contents for FA-H09-A20TL
Page 2: ......