LCDI POWER CORD AND PLUG
This air conditioner is equipped with a LCDI (Leakage Current Detection and Interruption)
power cord and plug. This cord consists of a shielded flexible cord with no termination on the
load side, and a LCDI attachment plug on the line side.
The LCDI power cord and plug will circuit trip the electrical power source if the nominal
current leakage between the cord shield and either load conductor exceeds a predetermined
value. The cord will remain out of power until the device is manually reset. This is intended to
protect against electric shock and to reduce the risk of a fire in the power cord or combustible
materials nearby. The cord shield is not grounded and must be considered a shock hazard if
exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI plug are used to check if the plug is functioning
properly. To test :
1.
Plug the power cord into a wall receptacle. The power pilot light should be ON.
2.
Press on the TEST button; circuit should trip, cutting off power to the air conditioner ; pilot
light is OFF.
3.
Press on the RESET button to restore power.
If a TEST is performed and the pilot light remains ON, a current leakage has been detected.
Do not use the air conditioner and/or attempt to reset the LCDI plug. Immediately contact
SUNRISE TRADEX Customer Service for technical support (see page 15).
WARNING :
1.
DO NOT PRESS the TEST button while the air conditioner is operating.
2.
The TEST and RESET buttons should not be used as ON and OFF switches.
3.
The cord and the plug are not intended to offer protection to externally connected
loads or supply circuits.
4.
The LCDI cord and plug are intended for indoor use only.
TEST BUTTON
RESET BUTTON
FRONT
BACK