Installation Instruction:
1.
Connect the protected equipment to “LOAD" T1
、
T2 terminal.
2.
Connect AC power cord to "LINE" L1
、
L2 terminal.
3.
The all terminals without voltage polarity restrictions.
4.
To ensure the effective protection of your equipment, the ground terminal “E” must be
grounding and grounding resistance should less 100
Ω
.
LED Indication:
1.
LED on: normal
2.
LED off: failed
Caution:
Make sure the grounding terminal "E" connect to the lightning protection grounding. Do
not access to the power ground wire, ground rod, and gas pipelines
Specification:
ITEM NO.
SP001P-AC110
SP001P-AC220
Wire >150V >300V
Nominal
peak
voltage
Wire~grounding >150V
>300V
Surge Current Capacity
6000A (8x20uS)
Surge Voltage Capacity
6,000V (1.2uS x 50 uS)
Response time
<0.1uS
Wire
<1mA (at150VAC)
<1mA (at300VAC)
Leakage
current
Wire~grounding <1mA
(at150VAC) <1mA
(at300VAC)
Max. Load Current
10Amp (Max)
Temperature
Operation: 0 to 55 C, Storage: -20 TO 85 c, Humidity: up to 95%
Connectors Terminal
Material Metal
Black
Dimensions W x H x D mm
87 x 67 x 27 mm
WEIGHT g
130 g
2
FORESIGHT CCTV INC. | 5863 Leslie Street, Unit#713, North York, Ontario,Canada, M2H 1J8 | http://www.foresight-cctv.com | 1-888-GO2-CCTV