- 14 -
6.3.1)
Serial
Settings
Features Option
Description
UART/RS-232/RS-485
E2S-UF/UI, E2S-RF/RI,
E2S-SF/SI
Serial Interface
SPI
E2S-PF/PI
For UART-TTL/RS-232/RS-485 Settings:
Features Default
All
option
Data Baud Rate
115200
921600, 115200, 57600, 38400,
19200, 9600, 4800, 2400, 1200
Data Bits
8
5, 6, 7, 8
Data Parity
None
Odd, Even, None
Stop Bits
1
1, 1.5, 2
Flow Control
None
Xon/Xoff, Hardware, None
For SPI Settings:
Features Default
All
option
Data Baud Rate
250KHz
1MHz, 750KHz, 500KHz,
400KHz, 250KHz, 200KHz
SPI Mode
0
0, 1, 2, 3
Differences between the SPI Mode 0~3:
MSB
D6
D5
D4
D3
D2
D1
LSB
MOSI
CPOL = 0, CPHA = 0
Capture SCLK = Rising Edge
SCLK Inactive = Low Level
CPOL = 1, CPHA = 1
Capture SCLK = Rising Edge
SCLK Inactive = High Level
CPOL = 0, CPHA = 1
Capture SCLK = Falling Edge
SCLK Inactive = Low Level
CPOL = 1, CPHA = 0
Capture SCLK = Falling Edge
SCLK Inactive = High Level
nSS
Mode 0
Mode 1
Mode 2
Mode 3
SCLK