Pinpoint Test K: The Hazard Lamps Are Inoperative

 

Refer to Wiring Diagrams Cell 

90

, Turn Signal/Stop/Hazard Lamps for schematic and connector information. 

Normal Operation 

The smart junction box (SJB) provides voltage to the indicator flasher relay through circuit SPB17 (RD). The indicator flasher relay routes the voltage to the multifunction switch through 
circuit CLS32 (BN/YE). When the hazard switch is engaged, the multifunction switch routes the voltage to all the turn lamps. 

Possible Causes

 

Fuse  

Circuit SPB17 (RD) open  

Circuit CLS32 (BN/YE) open, short to ground or voltage  

Indicator flasher relay  

Multifunction switch  

SJB 

 

 

PINPOINT TEST K: THE HAZARD LAMPS ARE INOPERATIVE 

NOTICE: 

Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

 

VOLTAGE

 

Ignition OFF.  

Disconnect: Multifunction Switch C202a.  

Ignition ON.  

Does the turn lamp continue to illuminate?

 

Yes

 

If the RH front turn lamp (and rear turn lamp if equipped with the STX package) is always on, 
REPAIR circuit CLS41 (GY/YE). TEST the system for normal operation.  
 
If the LH front turn lamp (and rear turn lamp if equipped with the STX package) is always on, 
REPAIR circuit CLS39 (VT/WH). TEST the system for normal operation.  
 

No

 

INSTALL a new multifunction switch. REFER 

Section 211-05

. TEST the system for normal 

operation.

 

J4 CHECK THE TURN LAMP GROUND CIRCUIT FOR AN OPEN

 

Disconnect: Inoperative Turn Lamp.  

Measure the resistance between the inoperative turn lamp, harness side 
and ground as follows:  
 

 

Is the resistance less than 5 ohms?

 

Inoperative Turn Lamp Connector-Pin

Circuit

LH front

C1023-1

GD121 (BK/YE)

RH front

C1043-1

GD123 (BK/GY)

LH rear

C413-1

GD121 (BK/YE)

RH rear

C416-1

GD121 (BK/YE)

Yes

 

GO to 

J5

.  

 

No

 

REPAIR the circuit in question. TEST the system for normal operation.

 

J5 CHECK THE MULTIFUNCTION SWITCH

 

Disconnect: Multifunction Switch.  

Carry out the multifunction switch component test. 

Refer to Wiring Diagrams Cell 

149

 for component testing. 

Is the multifunction switch OK?

 

Yes

 

If the RH turn lamp is inoperative, REPAIR circuit CLS41 (GY/YE). TEST the system for normal 
operation.  
 
If the LH turn lamp is inoperative, REPAIR circuit CLS39 (VT/WH). TEST the system for normal 
operation.  
 

No

 

INSTALL a new multifunction switch. REFER to 

Section 211-05

. TEST the system for normal 

operation.

Test Step

Result / Action to Take

 

K1 CHECK THE TURN SIGNAL LAMP OPERATION

 

Ignition ON.  

Place the multifunction switch in the RH and LH TURN positions.  

Do the turn signals operate correctly?

 

Yes

 

GO to 

K2

.  

 

No

 

GO to Pinpoint Test I

.

 

K2 CHECK THE HAZARD LAMPS

 

Ignition OFF.  

Turn on the hazard lamps.  

Are the lamps illuminated but not flashing?

 

Yes

 

GO to 

K9

.  

 

No

 

GO to 

K3

.

 

K3 CHECK FOR A SHORT TO GROUND

 

Listen to the indicator flasher relay.  

Is there a rapid clicking sound coming from the indicator flasher relay?

 

Yes

 

GO to 

K4

.  

 

No

 

GO to 

K5

.

 

K4 CHECK CIRCUIT CLS32 (BN/YE) FOR A SHORT TO GROUND

 

Disconnect: Multifunction Switch C202b.  

Is there a rapid clicking sound coming from the indicator flasher relay?

 

Yes

 

REPAIR the circuit. TEST the system for normal operation. 
 
 

No

 

INSTALL a new multifunction switch. REFER to 

Section 

211-05

. TEST the system for normal operation.

 

K5 CHECK THE VOLTAGE TO THE INDICATOR FLASHER RELAY

 

Page 5 of 7

2007 Ranger Workshop Manual

6/20/2011

http://www.fordtechservice.dealerconnection.com/pubs/content/~WS7L/~MUS~LEN/20/S...

Summary of Contents for Ranger 2007

Page 1: ...possible before proceeding to the next step 4 If the concern is not visually evident verify the symptom GO to Symptom Chart Symptom Chart Pinpoint Tests SECTION 417 01 Exterior Lighting 2007 Ranger Workshop Manual DIAGNOSIS AND TESTING Procedure revision date 09 21 2007 Special Tool s 73III Automotive Meter 105 R0057 or equivalent Flex Probe Kit 105 R025C or equivalent Mechanical Electrical Multif...

Page 2: ...S ARE INOPERATIVE NOTICE Use the correct probe adapter s when making measurements Failure to use the correct probe adapter s may damage the connector Test Step Result Action to Take I1 CHECK THE TURN SIGNALS Ignition ON Place the multifunction switch in the LH and RH TURN positions Do the turn signal lamps illuminate but not flash Yes GO to I2 No GO to I4 I2 CHECK CIRCUIT CLS42 VT BN FOR A SHORT T...

Page 3: ...F Disconnect Indicator Flasher Relay C2047 Ignition ON Measure the voltage between the indicator flasher relay C2047 5 circuit CBP20 YE VT harness side and ground Is the voltage greater than 10 volts Yes GO to I10 No VERIFY the SJB fuse 20 10A is OK If OK GO to I9 I9 CHECK CIRCUIT CBP20 YE VT FOR AN OPEN Ignition OFF Disconnect SJB C2280b Measure the resistance between the SJB C2280b 19 circuit CB...

Page 4: ...h PINPOINT TEST J ONE TURN SIGNAL HAZARD LAMP IS INOPERATIVE ALWAYS ON NOTICE Use the correct probe adapter s when making measurements Failure to use the correct probe adapter s may damage the connector Is the resistance less than 5 ohms No REPAIR the circuit TEST the system for normal operation I12 CHECK FOR VOLTAGE TO THE MULTIFUNCTION SWITCH Connect Indicator Flasher Relay C2047 Ignition ON Mea...

Page 5: ... Lamp Connector Pin Circuit LH front C1023 1 GD121 BK YE RH front C1043 1 GD123 BK GY LH rear C413 1 GD121 BK YE RH rear C416 1 GD121 BK YE Yes GO to J5 No REPAIR the circuit in question TEST the system for normal operation J5 CHECK THE MULTIFUNCTION SWITCH Disconnect Multifunction Switch Carry out the multifunction switch component test Refer to Wiring Diagrams Cell 149 for component testing Is t...

Page 6: ...ION SWITCH Carry out the multifunction switch component test Refer to Wiring Diagrams Cell 149 for component testing Is the multifunction switch OK Yes INSTALL a new indicator flasher relay TEST the system for normal operation No INSTALL a new multifunction switch REFER to Section 211 05 TEST the system for normal operation K9 CHECK FOR A SHORT TO VOLTAGE Disconnect Indicator Flasher Relay C2047 M...

Page 7: ...erate the system and verify the concern is still present Is the concern still present Yes INSTALL a new SJB REFER to Section 419 10 TEST the system for normal operation No The system is operating correctly at this time The concern may have been caused by a loose or corroded connector Page 7 of 7 2007 Ranger Workshop Manual 6 20 2011 http www fordtechservice dealerconnection com pubs content WS7L M...

Reviews: