Turn Signal and Hazard Lamps    

  Printable View (206 KB)

  

 

 

 

 

Principles of Operation

 

NOTE: 

The smart junction box (SJB) is also known as the generic electronic module (GEM). 

Turn Signal Lamps

 

Voltage is supplied by the SJB to the indicator flasher relay when the ignition switch is in the RUN position. When the multifunction switch is placed in the LH or RH TURN position, voltage 
is routed to the multifunction switch, which then routes the voltage to the turn lamps. The electronic flasher relay then cycles the voltage on and off approximately 80 times per minute. If a 
front or rear turn bulb is inoperative, the electronic flasher relay cycles the voltage on and off approximately 160 times per minute. 

Hazard Lamps

 

Voltage is supplied by the SJB to the indicator flasher relay at all times. When the hazard switch is engaged, voltage is routed to the multifunction switch, which then routes the voltage to all 
the turn lamps. 

 

 

Inspection and Verification

 

1. Verify the customer concern. 

2. Visually inspect the following for obvious signs of mechanical or electrical damage. 

 
 

 Visual Inspection Chart

 

 

3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step. 

4. If the concern is not visually evident, verify the symptom. GO to 

Symptom Chart

 

 

Symptom Chart

 

 

 

 

 

Pinpoint Tests

 

SECTION 417-01: Exterior Lighting 

2007 Ranger Workshop Manual 

DIAGNOSIS AND TESTING 

Procedure revision date: 09/21/2007

Special Tool(s)

73III Automotive Meter 
105-R0057 or equivalent

Flex Probe Kit 
105-R025C or equivalent

Mechanical

Electrical

Multifunction switch 

Smart junction box (SJB) fuse(s): 

17 (15A) (hazard lamps)  

20 (10A) (turn lamps) 

Indicator flasher relay  

Circuitry  

SJB 

Symptom Chart

Condition

Possible Sources

Action

The turn signal lamps are inoperative 

Fuse  

Circuitry  

Indicator flasher relay 

Multifunction switch  

Smart junction box 
(SJB)  

GO to Pinpoint Test I

.  

The turn signal lamps are always on 

Multifunction switch  

INSTALL a new multifunction switch. REFER to 

Section 211-05

. TEST the 

system for normal operation.  

One turn signal/hazard lamp is 
inoperative/always on 

Circuitry  

Multifunction switch  

GO to Pinpoint Test J

.  

The hazard lamps are inoperative 

Fuse  

Circuitry  

Indicator flasher relay 

Multifunction switch  

SJB  

GO to Pinpoint Test K

.  

The hazard lamps are always on 

Multifunction switch  

INSTALL a new multifunction switch. REFER to 

Section 211-05

. TEST the 

system for normal operation.  

Page 1 of 7

2007 Ranger Workshop Manual

6/20/2011

http://www.fordtechservice.dealerconnection.com/pubs/content/~WS7L/~MUS~LEN/20/S...

Summary of Contents for Ranger 2007

Page 1: ...possible before proceeding to the next step 4 If the concern is not visually evident verify the symptom GO to Symptom Chart Symptom Chart Pinpoint Tests SECTION 417 01 Exterior Lighting 2007 Ranger Workshop Manual DIAGNOSIS AND TESTING Procedure revision date 09 21 2007 Special Tool s 73III Automotive Meter 105 R0057 or equivalent Flex Probe Kit 105 R025C or equivalent Mechanical Electrical Multif...

Page 2: ...S ARE INOPERATIVE NOTICE Use the correct probe adapter s when making measurements Failure to use the correct probe adapter s may damage the connector Test Step Result Action to Take I1 CHECK THE TURN SIGNALS Ignition ON Place the multifunction switch in the LH and RH TURN positions Do the turn signal lamps illuminate but not flash Yes GO to I2 No GO to I4 I2 CHECK CIRCUIT CLS42 VT BN FOR A SHORT T...

Page 3: ...F Disconnect Indicator Flasher Relay C2047 Ignition ON Measure the voltage between the indicator flasher relay C2047 5 circuit CBP20 YE VT harness side and ground Is the voltage greater than 10 volts Yes GO to I10 No VERIFY the SJB fuse 20 10A is OK If OK GO to I9 I9 CHECK CIRCUIT CBP20 YE VT FOR AN OPEN Ignition OFF Disconnect SJB C2280b Measure the resistance between the SJB C2280b 19 circuit CB...

Page 4: ...h PINPOINT TEST J ONE TURN SIGNAL HAZARD LAMP IS INOPERATIVE ALWAYS ON NOTICE Use the correct probe adapter s when making measurements Failure to use the correct probe adapter s may damage the connector Is the resistance less than 5 ohms No REPAIR the circuit TEST the system for normal operation I12 CHECK FOR VOLTAGE TO THE MULTIFUNCTION SWITCH Connect Indicator Flasher Relay C2047 Ignition ON Mea...

Page 5: ... Lamp Connector Pin Circuit LH front C1023 1 GD121 BK YE RH front C1043 1 GD123 BK GY LH rear C413 1 GD121 BK YE RH rear C416 1 GD121 BK YE Yes GO to J5 No REPAIR the circuit in question TEST the system for normal operation J5 CHECK THE MULTIFUNCTION SWITCH Disconnect Multifunction Switch Carry out the multifunction switch component test Refer to Wiring Diagrams Cell 149 for component testing Is t...

Page 6: ...ION SWITCH Carry out the multifunction switch component test Refer to Wiring Diagrams Cell 149 for component testing Is the multifunction switch OK Yes INSTALL a new indicator flasher relay TEST the system for normal operation No INSTALL a new multifunction switch REFER to Section 211 05 TEST the system for normal operation K9 CHECK FOR A SHORT TO VOLTAGE Disconnect Indicator Flasher Relay C2047 M...

Page 7: ...erate the system and verify the concern is still present Is the concern still present Yes INSTALL a new SJB REFER to Section 419 10 TEST the system for normal operation No The system is operating correctly at this time The concern may have been caused by a loose or corroded connector Page 7 of 7 2007 Ranger Workshop Manual 6 20 2011 http www fordtechservice dealerconnection com pubs content WS7L M...