TECHNICAL DATA
Model
FX1-95
Nominal voltage
230-240V~50Hz
Power consumption
950W
Variable speed
0-380 m/min
belt size
533 x 76mm
Sanding surface
Weight
6 kg
10
SOUND EMISSIONS
Noise values measured according to relevant standard. (K = 3)
Acoustic pressure level LpA
90 dB(A)
Acoustic power level LwA
101 dB(A)
ATTENTION! The sound power level may exceed 85 dB(A), in
this case individual hearing protection shall be worn.
aw (Vibration)
Max 5.1 m/s²
K = 1.5 m/s²
11
SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a
particular connecting cable which is available from our service department.
Replacement of the connecting cable must only be carried out by our service
department (see last page) or by a qualified person (qualified electrician).
12
STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool
and dry place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don’t keep it in plastic bags to avoid humidity build
-up.
13
WARRANTY
This product is warranted as provided by law for a 24 -month period effective
from the date of purchase by the first user.
This warranty covers all material or production flaws excluding: batteries,
chargers, defective parts subject to normal wear & tear such as bearings,
brushes, cables, and plugs, or accessories such as drills, drill bits, saw blades,
etc. ; damage or defects resulting from maltreatment, accidents or alterations;
nor the cost of transportation.
Damage and/or defects resulting from inappropriate use also do not fall under
the warranty provisions.
We also disclaim all liability for any bodily injury resulting from inappropriate
use of the tool.