Dismantling 

Proceed in reverse order to mounting 

WARNING Accessories can be hot after use.  Don

t touch the 

tip of accessory by hand! Please always use protective gloves 

to remove the accessory. 

8.3

 

Additional handle (fig; 4) 

For safety reasons you must only use the demolition hammer 

with the additional handle. 

ƒ

 

The additional handle (1) enables you to achieve better stability while using 

the demolition hammer. 

ƒ

 

The additional handle can be turned into any required position. To do so, undo 

the lock knob (8) of auxiliary handle. Then turn the handle into the most 

comfortable working position and tighten the lock knob (8) again. 

Important.  To  avoid  danger,  the  machine  must  only  be  held 

using  the  two  handles  (2-3).  Otherwise  you  may  suffer  an 

electric shock if you chisel into cables. 

9

 

LUBRICATION - OIL LEVEL 

Check the oil level before using the machine. 

ƒ

 

Place the machine on the floor with the tool chuck (5), pointing downwards. 

ƒ

 

The oil must be at least 3 mm above the bottom of the inspection window (6). 

The oil should be changed after around 40-50 hours of use. 

Recommended oil: 25ml SAE 15W/40 or an alternative of the same quality. 

9.1

 

Oil change (Fig. 5) 

ƒ

 

Switch off the machine and disconnect the plug from the socket. 

ƒ

 

Undo the hexagonal head screw with the inspection window (6) using the 

wrench (7) and drain the oil. 

ƒ

 

To prevent the oil from running out in an uncontrolled manner, hold a small 

metal chute under the opening and collect the oil in a vessel until it has fully 

drained out of the machine. 

Important:  The  waste  oil  must  be  disposed  of  in  the 

appropriate collection point for waste oil. 

ƒ

 

Add new oil (approx. 25 ml) through the oil filler opening until the oil level 

reaches the required level. Tighten the hexagonal screw again. 

ƒ

 

Re-check the oil level after a short period of operation. 

 

 

Summary of Contents for FX1-1050

Page 1: ...0 DEMOLITION HAMMER MARTEAU PIQUEUR Operation manual and security instructions inside the box Use safety glasses Keep this tool away from children Ford Motor Company trademarks and trade dress used un...

Page 2: ...l safety 4 6 4 Power tool use and care 5 6 5 Service 5 6 6 For safe operation 5 7 APPLICATION 7 7 1 Switching On Off Fig 2 7 7 2 How to use the demolition hammer 7 8 CHANGING TOOLS 7 8 1 Mounting chis...

Page 3: ...ng bolt 5 Tool chuck 6 Inspection window Oil filler opening 7 Wrench 8 Lock knob of auxiliary handle 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports...

Page 4: ...rk in a clean and uncluttered workspace Your work area should be correctly lit 5 Store the tool in a dry place far from sources of heat or of dangerous vapours ideal 10 to 15 C Do not operate your too...

Page 5: ...thed Do not expose power tools to rain or wet conditions If water gets inside a power tool it will increase the risk of a lethal electric shock Do not damage the cord Never use the cord for carrying p...

Page 6: ...hen not in use out of the reach of children and do not allow people who are not familiar with the power tool or these instructions to operate it Power tools are potentially dangerous in the hands of u...

Page 7: ...f damaged have repaired by an authorized service facility Inspect extension cords periodically and replace if damaged Keep handles dry clean and free from oil and grease Disconnect tools Disconnect wh...

Page 8: ...a moderate work rate the use of too much force will impair efficiency CAUTION After long time of use the cylinder case becomes hot Therefore be careful not to burn your hands WARNING Don t apply big p...

Page 9: ...sel into cables 9 LUBRICATION OIL LEVEL Check the oil level before using the machine Place the machine on the floor with the tool chuck 5 pointing downwards The oil must be at least 3 mm above the bot...

Page 10: ...DS Hex Impact Rate 2000 beats min 12 NOISE Noise emission values measured according to relevant standard K 3 Acoustic pressure level LpA 99 dB A Acoustic power level LwA 104 dB A ATTENTION Wear hearin...

Page 11: ...plicable to the unit accompanied by proof of purchase 15 ENVIRONMENT Should your machine need replacement after extended use do not put it in the domestic waste but dispose of it in an environmentally...

Reviews: