P a g e
|
9
The torque increasesduring the 5 first seconds of operation. When assembling or
disassembling a bolt, you will keep the tool running for more than 5 seconds, but
it does not mean the torque will continue to increase.
10
TECHNICAL DATA
Model n°
FCA-50
Nominal voltage
220-240V
Power consumption
1010W
No load speed
2200 min
-1
Max. Torque
450 Nm
Square drive
½
” (13 mm)
Weight
3.89kg
11
NOISE
Noise values measured according to relevant standard. (K = 3)
Acoustic pressure level LpA
98.2 dB(A)
Acoustic power level LwA
109.2 dB(A)
ATTENTION! The sound power level may exceed 85 dB(A), in
this case individual hearing protection shall be worn.
aw (Vibration)
18.939m/s
²
K = 1.5 m/s
²
Warning!
The vibration emission during actual use of the power tool can differ
from the declared total value depending on the ways in which the tool is used.
There is the need to identify safety measures to protect the operator that are
based on an estimation of exposure in the actual conditions of use (taking account
of all parts of the operating cycle).
12
CLEANING AND MAINTENANCE
Before any intervention on product, ensure that product is
disconnected from its power source.
12.1
Cleaning.
§
Clean the tool only with a moist cloth. Use no alcohol, petrol, or chemicals for
cleaning. Hold the ventilation slits open.
§
Do not put in or immerse product in water or any other liquid.
§
Clean ventilation holes with a soft brush.
§
Have your tool repaired by a qualified person.
§
Repairs should only be carried out by qualified persons using original spare
parts, otherwise it may result in considerable danger to the user.
12.2
Storage
§
Keep the product, user manual and accessories in the original packaging.
§
It is recommended to store the tool in a clean, dry area, and place it out of
reach of children, either stored in height or locked up.