Are the voltages greater than 10 volts?
Yes
REINSTALL fuses, GO to
A2
.
No
REPAIR the BJB. REPEAT the FEM self-test, CLEAR the DTCs.
A2
CHECK CIRCUIT 1452 (LB/RD) AND CIRCUIT 1119 (RD)
FEM C346
FEM C190
FEM C192
Measure the voltage between FEM C346 Pin 1, Circuit 1452 (LB/RD), harness side and ground; and between
FEM C190 Pin 6, Circuit 1119 (RD), harness side and ground.
Is the voltage greater than 10 volts?
Yes
GO to
A3
.
No
REPAIR Circuit 1119 (RD). REPEAT the FEM self-test, CLEAR the DTCs.
A3
CHECK CIRCUIT 1205 (BK) FOR OPEN
FEM C348
Measure the resistance between ground and the FEM, as follows:
FEM Connector Pin
Circuit
C190
12 1205 (BK)
C192
11 1205 (BK)