Diagnosing hardware problems |
20
Color
State
Status
• Fan redundancy lost, sufficient system cooling maintained
Note:
This does not apply to non-redundant systems.
• Power supply predictive failure
• Power supply redundancy lost
Note:
This does not apply to non-redundant systems.
• Correctable errors over a threshold of 10 and migrating to
a mirrored DIMM (memory mirroring)
Note:
This indicates the appliance no longer has spare
DIMMs indicating a redundancy lost condition. The
corresponding DIMM indicator light should light up.
Blink
Non-fatal alarm — System is likely to fail:
• CATERR asserted
• Critical temperature threshold asserted
• Critical voltage threshold asserted
• VRD hot asserted
• SMI Timeout asserted
Amber
Solid
Fatal alarm — System has failed or shut down:
• CPU missing
• Thermal Trip asserted
• Non-recoverable temperature threshold asserted
• Non-recoverable voltage threshold asserted
• Power fault/Power Control Failure
• Fan redundancy lost, insufficient system cooling
Note:
This does not apply to non-redundant systems.
• Power supply redundancy lost insufficient system power
Note:
This does not apply to non-redundant systems.
Off
Off
System powered off